Your Position: Home > Control System > PLC > Delta PLC > PLC DC24V 8 DI 4 AI 6 DO 2 AO transistor Delta DVP20SX211T New

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

PLC DC24V 8 DI 4 AI 6 DO 2 AO transistor Delta DVP20SX211T New

prevnext

PLC DC24V 8 DI 4 AI 6 DO 2 AO transistor  Delta DVP20SX211T New
  • Market price: $ 772.2
  • Shop price: $ 234.0
  • Goods click count: 682
  • Total:
  • Quantity:
Add to cart collect
  

Description

DVP20SX211T Delta PLC 24VDC 8(4AI) 6(2AO) transistor (NPN) output Analog Original brand new


Features

The 2nd generation DVP-SX2 series slim type PLC offers 14 digital points and built-in 12-bit analog I/O points. It is extendable with DVP-S series left-side and right-side extension modules.

Specifications

*MPU points: 20 (8DI/6DO, 4AI/2AO) 
*Max. I/O points: 494 (14 + 480) 
*Program capacity: 16k steps 
*COM port: Built-in RS-232, RS-485 & USB ports, compatible with ASCII/RTU protocol. Can be master or slave. 
*High-Speed Pulse Output: Supports 2 points (Y0, Y2) of 100kHz and 2 points (Y1, Y3) of 10kHz independent high-speed pulse output. 
*Built-in High-Speed Counters 

Model

Item

DVP20SX211R

DVP20SX211T

DVP20SX211S

Power supply voltage

24 VDC (-15 to 20%)

(with counter-connection protection on the polarity of DC input power)

DVPPS01/PS02: input 100 to 240 VAC, output 24 VDC/1A (PS02: 2A)

Inrush current

Max. 7.5 A@24 VDC

Fuse capacity

2.5 A/30 VDC, Polyswitch

Power consumption

4.7W

4W

4W

Insulation resistance

> 5 M Ohm (all I/O point-to-ground: 500 VDC)

Noise immunity

ESD (IEC 61131-2, IEC 61000-4-2): 8kV Air Discharge

EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2kV, Digital I/O: 1kV,

Analog & Communication I/O: 1kV

RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m

Grounding

The diameter of grounding wire cannot be smaller than the wire diameter of terminals L and N (All DVP units should be grounded directly to the ground pole).

Operation / storage

Operation: 0 to 55°C (temp.), 50 to 95% (humidity), Pollution degree 2

Storage: -25 to 70°C (temp.), 5 to 95% (humidity)

Vibration / shock resistance

International standards: IEC61131-2, IEC 68-2-6 (TEST

Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)

Weight (g)

243

224

227

Applications

Used for PID temperature/humidity control, 2-axis AC motor drive constant speed control, temperature control using a analog signal monitoring of a whole factory. (PLC EASY LINK)



  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: