No comment |
>
Control System >
PLC >
Delta PLC >
DVP16EH00T3 Delta PLC 100-240VAC 8DI 8DO transistor output Standard Original brand newDVP16EH00T3 Delta PLC 100-240VAC 8DI 8DO transistor output Standard Original brand new
Features
The new generation DVP-EH3 PLC is the high-end model of the Delta DVP-E series. It provides larger program capacity and data registers for more demanding and complex applications.
Specification
Model Items | 16EH 00_3 | 20EH 00_3 | 32EH 00_3 | 32EH 00_M3 | 40EH 00_3 | 48EH 00_3 | 64EH 00_3 | 80EH 00_3 | |
Power supply voltage | 100 ~ 240VAC (-15% ~ 10%); 50/60Hz + -5% | ||||||||
Fuse capacity | 2A/250VAC | ||||||||
Power consumption | 50VA | 60VA | 80VA | ||||||
DC24V current output | 500mA | ||||||||
Power supply protection | DC24V output short circuit protection | ||||||||
Voltage withstand | 1,500VAC (Primary-secondary), 1,500VAC (Primary-PE), 500VAC (Secondary-PE) | ||||||||
Insulation resistance | > 5M Ohmat 500VDC (between all I/O points and ground) | ||||||||
Noise immunity | ESD: 8KV Air Discharge EFT: Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 250V Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV, RS: 26MHz ~ 1GHz, 10V/m | ||||||||
Grounding | The diameter of grounding wire shall not be less than that of L, N terminal of the power supply. (When many PLCs are in use at the same time, please make sure every PLC is properly grounded.) | ||||||||
Operation/ storage | Operation: 0 °C ~55 °C (temperature), 50~95% (humidity), pollution degree 2 Storage: -25 °C ~70 °C (temperature), 5~95% (humidity) | ||||||||
Vibration/shock resistance | International standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/ IEC61131-2 & IEC 68-2-27 (TEST Ea) | ||||||||
Weight (g) | R | 500 | 520 | 652 | 644 | 710 | 748 | 836 | 948 |
T | 480 | 500 | 612 | 644 | 675 | 688 | 756 | 848 |
DVP16EH00T3 Delta PLC 100-240VAC 8DI 8DO transistor output Standard Original brand new
Features
The new generation DVP-EH3 PLC is the high-end model of the Delta DVP-E series. It provides larger program capacity and data registers for more demanding and complex applications.
Specification
Model
Items
16EH
00_3
20EH
00_3
32EH
00_3
32EH
00_M3
40EH
00_3
48EH
00_3
64EH
00_3
80EH
00_3
Power supply
voltage
100 ~ 240VAC (-15% ~ 10%); 50/60Hz + -5%
Fuse capacity
2A/250VAC
Power
consumption
50VA
60VA
80VA
DC24V current
output
500mA
Power supply
protection
DC24V output short circuit protection
Voltage
withstand
1,500VAC (Primary-secondary), 1,500VAC (Primary-PE),
500VAC (Secondary-PE)
Insulation
resistance
> 5M Ohmat 500VDC (between all I/O points and ground)
Noise immunity
ESD: 8KV Air Discharge
EFT: Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 250V
Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV, RS: 26MHz ~
1GHz, 10V/m
Grounding
The diameter of grounding wire shall not be less than that of L, N terminal of
the power supply. (When many PLCs are in use at the same time, please
make sure every PLC is properly grounded.)
Operation/
storage
Operation: 0 °C ~55 °C (temperature), 50~95% (humidity), pollution degree 2
Storage: -25 °C ~70 °C (temperature), 5~95% (humidity)
Vibration/shock
resistance
International standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/ IEC61131-2 &
IEC 68-2-27 (TEST Ea)
Weight (g)
R
500
520
652
644
710
748
836
948
T
480
500
612
644
675
688
756
848
No comment |