No comment |
>
Motion Control System >
Stepper Drive&Motor >
Other NEMA+Flange >
2PH 56mm NEMA23 3A 1.5NM 214ozin 24-70VDC Stepper motor Drive kits 2S56Q-02976+2M8602PH 56mm NEMA23 3A 1.5NM 214ozin 24-70VDC Stepper motor Drive kits 2S56Q-02976+2M860
2S56Q-02976+2M860
Hybrid Servo Motor 2S56Q-02976
Specifications
Model
2S56Q-02976
Step Angle
1.8centigrade degree±5%
Phase Current (A)
3
Holding Torque (Nm)
1.5
Damping Torque (Nm)
0.07
Winding Resistance (ohm)
0.95±10%
Winding Inductance(mH)
3.4±20%
Motor Inertia (Kg.com²)
0.46
Motor Length L(mm)
76
Number of Lead Wires
4
Insulation Class
B
Withstand Voltage Level
500VAC,one minute
Max.Axial Load (N)
15
Max.Readial Load (N)
75
Operating Temperature
-20centigrade degree~50centigrade degree
Surface Temperature Rise
Max.80centigrade degree (Rated Phase Current after Two Phases are Connected)
Insulation Impedance
Minimum 100Mohm,500VDC
Weight (Kg)
1
Lead Wire Length (mm)
300±5
Hybrid Servo Drive 2M860
Features:
The Maximum Supply Voltage can Reach 80V, Which can Provide Better Dynamic Drive Performance;
The Bipolar Constant Current Drive Mode is Taken with a Maximum Drive Current up to 6.0A Per Phase, Which can Drive any Two-Phase Bipolar Hybrid Stepper Motors with a Current Less than 6.0A;
The Drive Output Phase Current of a Motor can be Regulated through the DIP Switch, to Match Motors of Different Specifications;
Supporting Automatic Half Current Function of Motors in Statically Locked Status, Which can Greatly Reduce Heat Dissipation of the Motors;
A Dedicated Control Chip is Used, with a Maximum of 256/200 Subdivisions. The Subdivision Function can be Set by the DIP Switch, to Ensure the Best Operation Stability;
Supporting Offline Function So That the Output Current of a Motor can be Cut Off If Necessary;
Optical Coupling Devices are Used for the Isolation of the Input Circuit of the Control Signals to Reduce Interference of External Noises.
Supporting Such Protection Functions as Overvoltage, Over Current, Out-of-Phase, and Output Short Circuit;
If the Drive Red LED Indicator Lights up, It Indicates that It Is in Protected Status. Turn Off the Power Supply, and Recheck the Wiring. It can Only be Operated Properly After the Power Supply is Turned on Again;
Specification
Model
2M860
Supply Voltage
DC 24V ~70V
Output Phase Current
2.5A~6.0A
Control Signal Input Current
6~16mA
Cooling Method
Natural Air Cooling
Operating Environment
Avoid the Environment with a Great Amount of Metallic Powder, Oil Mist, or Erosive Gases
Operating Temperature
-10centigrade degree~+45centigrade degree
Operating Humidity
< 85% (Non-Condensing)
Weight
0.7 Kg
No comment |