2PH 42mm NEMA17 1.2A 0.32NM 46ozin12-40VDC Stepper motor Drive kits 2S42Q-03848+2M4122PH 42mm NEMA17 1.2A 0.32NM 46ozin12-40VDC Stepper motor Drive kits 2S42Q-03848+2M412
2S42Q-03848+2M412
Hybrid Servo Motor 2S42Q-03848
Specifications
Model | 2S42Q-03848 |
Step Angle | 1.8centigrade degree±5% |
Phase Current (A) | 1.2 |
Holding Torque (Nm) | 0.32 |
Damping Torque (Nm) | 0.02 |
Winding Resistance (ohm) | 3.2±10% |
Winding Inductance(mH) | 6.0±20% |
Motor Inertia (Kg.com²) | 0.08 |
Motor Length L(mm) | 48 |
Number of Lead Wires | 4 |
Insulation Class | B |
Withstand Voltage Level | 500VAC,One Minute |
Max.Axial Load (N) | 10 |
Max.Readial Load (N) | 28 |
Operating Temperature | -20centigrade degree~50centigrade degree |
Surface Temperature Rise | Max.80centigrade degree (Rated Phase Current after Two Phases are Connected) |
Insulation Impedance | Minimum 100Mohm,500VDC |
Weight (Kg) | 0.36 |
Lead Wire Length (mm) | 1000±10 |
Hybrid Servo Drive 2M412
Features:
The Maximum Supply Voltage can Reach 40V;
The Bipolar Constant Current Drive Mode is Taken, with a Maximum Drive Current up to 1.2A Per Phase, Which can Drive any two-Phase Bipolar Hybrid Stepper Motors with a Current Less than 1.2A;
The Drive Output Phase Current of a Motor can be Regulated Through the DIP Switch, to Match Motors of Different Specifications;
A DIP Switch is Used to Set the Automatic Half Current Function of Motors in Statically Locked Status, which can Greatly Reduce Heat Dissipation of the Motors;
A Dedicated Control Chip is Used, with a Maximum of 256/200 Subdivisions. The Subdivision Function can be Set by the DIP Switch, to Ensure the Best Operation Stability;
Optical Coupling Devices are Used for the Isolation of the Input Circuit of the Control Signals to Reduce Interference of External Noises.
Specification
Model | 2M412 |
Supply Voltage | DC 12V ~40V |
Output Phase Current | 0.2A~ 1.2A |
Control Signal Input Current | 6~16mA |
Cooling Method | Natural Air Cooling |
Operating Environment | Avoid the Environment with a Great Amount of Metallic Powder, Oil Mist, or Erosive Gases |
Operating Temperature | -10centigrade degree~ +45centigrade degree |
Operating Humidity | < 85% (Non-Condensing) |
Weight | 0.13 Kg |
2PH 42mm NEMA17 1.2A 0.32NM 46ozin12-40VDC Stepper motor Drive kits 2S42Q-03848+2M412
2S42Q-03848+2M412
Hybrid Servo Motor 2S42Q-03848
Specifications
Model
2S42Q-03848
Step Angle
1.8centigrade degree±5%
Phase Current (A)
1.2
Holding Torque (Nm)
0.32
Damping Torque (Nm)
0.02
Winding Resistance (ohm)
3.2±10%
Winding Inductance(mH)
6.0±20%
Motor Inertia (Kg.com²)
0.08
Motor Length L(mm)
48
Number of Lead Wires
4
Insulation Class
B
Withstand Voltage Level
500VAC,One Minute
Max.Axial Load (N)
10
Max.Readial Load (N)
28
Operating Temperature
-20centigrade degree~50centigrade degree
Surface Temperature Rise
Max.80centigrade degree (Rated Phase Current after Two Phases are Connected)
Insulation Impedance
Minimum 100Mohm,500VDC
Weight (Kg)
0.36
Lead Wire Length (mm)
1000±10
Hybrid Servo Drive 2M412
Features:
The Maximum Supply Voltage can Reach 40V;
The Bipolar Constant Current Drive Mode is Taken, with a Maximum Drive Current up to 1.2A Per Phase, Which can Drive any two-Phase Bipolar Hybrid Stepper Motors with a Current Less than 1.2A;
The Drive Output Phase Current of a Motor can be Regulated Through the DIP Switch, to Match Motors of Different Specifications;
A DIP Switch is Used to Set the Automatic Half Current Function of Motors in Statically Locked Status, which can Greatly Reduce Heat Dissipation of the Motors;
A Dedicated Control Chip is Used, with a Maximum of 256/200 Subdivisions. The Subdivision Function can be Set by the DIP Switch, to Ensure the Best Operation Stability;
Optical Coupling Devices are Used for the Isolation of the Input Circuit of the Control Signals to Reduce Interference of External Noises.
Specification
Model
2M412
Supply Voltage
DC 12V ~40V
Output Phase Current
0.2A~ 1.2A
Control Signal Input Current
6~16mA
Cooling Method
Natural Air Cooling
Operating Environment
Avoid the Environment with a Great Amount of Metallic Powder, Oil Mist, or Erosive Gases
Operating Temperature
-10centigrade degree~ +45centigrade degree
Operating Humidity
< 85% (Non-Condensing)
Weight
0.13 Kg