DVP30ES00R2 Delta PLC 100-240VAC 18DI 12DO relay output Standard Original brand new

prevnext

DVP30ES00R2 Delta PLC 100-240VAC 18DI 12DO relay output Standard Original brand new
  • Market price: $ 541.2
  • Shop price: $ 164.0
  • Goods click count: 413
  • Total:
  • Quantity:
Add to cart collect
  

Description

DVP30ES00R2 Delta PLC 100-240VAC 18DI 12DO relay output Standard Original brand new


Features

ES series is the representative MPU for basic sequential control as well as the most cost-effective small PLC.

Specifications

*MPU points: 14 / 24 / 32 / 40 / 60 
*Max. I/O points: 256 
*Program capacity: 4K Steps 
*Communication port: Built-in RS-232 and RS-485, compatible with MODBUS ASCII / RTU communication protocol. 
*High-speed pulse output: Supports 2-point (Y0, Y1) independent high-speed pulse output of up to 10KHz. 
*Built-in 4-point high-speed counter 

     Model

Item

DVP-

14ES00_

DVP-

24ES00_

DVP-

30ES00_

DVP-

32ES00_

DVP-

40ES00_

DVP-

60ES00_

DVP-

20EX00_

DVP-

24ES11_

DVP-

20EX11_

Power Supply

Voltage

100 ~ 240V AC (-15% ~ 10%), 50/60Hz + - 5%

24V DC (-15% ~

10%)

Operation

Specification

The PLC start to operate at power supply of 95 ~ 100V AC. If the voltage of

power supply drops to 70V AC, the PLC will stop. Maximum power loss time is 10ms or less.

Maximum power loss

time is 5ms or less.

Fuse

2A/250V AC

Power

Consumption

20VA

25VA

30VA

30VA

30VA

35VA

30VA

6.5W

8W

DC24V Supply

Current

400mA

/

Power

Protection

DC24V output short circuit

DC24V input polarity

Voltage

Withstand

1,500 VAC (Primary-secondary), 1,500V AC (Primary-PE), 500V AC (Secondary-PE)

Insulation

Resistance

> 5 M Ohm at 500V DC (Between all inputs/outputs and earth)

Noise Immunity

ESD: 8KV Air Discharge

EFT: Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 250V

RS: 26MHz ~ 1GHz, 10V/m

Grounding

The diameter of grounding wire cannot be smaller than the wire diameter of terminals L and N (All DVP

units should be grounded directly to the ground pole).

Environment

Operation: 0°C ~ 55°C (temperature), 50 ~ 95% (humidity), Pollution degree2

Storage: -25°C ~ 70°C (temperature), 5 ~ 95% (humidity)

Vibration /

Shock

Resistance

Standard: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)

Weight (g)

400