Your Position: Home > Motion Control System > AC Servo System > Kinco > AC220V 750W 3.9A 2.39NM 3Krpm 80mm Brake AC Servo Motor Drive kits SMH80S-0075-30ABK-3LKH+ED430-0075-AA-K-000 with 3M ca

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

AC220V 750W 3.9A 2.39NM 3Krpm 80mm Brake AC Servo Motor Drive kits SMH80S-0075-30ABK-3LKH+ED430-0075-AA-K-000 with 3M ca

prevnext

AC220V 750W 3.9A 2.39NM 3Krpm 80mm Brake AC Servo Motor Drive kits SMH80S-0075-30ABK-3LKH+ED430-0075-AA-K-000 with 3M ca
  • NO.: AC220V
  • Weight: 7.000 KG
  • Market price: $ 3649.8
  • Shop price: $ 1106.0
  • Goods click count: 373
  • Total:
  • Quantity:
Add to cart collect
  

Description

AC220V 750W 3.9A 2.39NM 3Krpm 80mm Brake AC Servo Motor Drive kits SMH80S-0075-30ABK-3LKH+ED430-0075-AA-K-000 with 3M cable

Motor + Drive: SMH80S-0075-30ABK-3LKH+ED430-0075-AA-K-000

1 Motor Specifications

Motor series

Small inertia, flange size 80mm

Model

     SMH80S-0075-30ABK-3LKH            

DC link voltage UDC

300

Continuous
 performance

Rated power   PN (W)

750

Rated torque   TN (Nm)

2.39

Rated speed   nN (rpm)

3000

Rated current IN (A)

3.9

Maximum torque         Tm (Nm)

7.17

Maximum current        Im (A)

11.7

Standstill torque      TS (Nm)

2.63

Standstill current     IS (A)

4.4

Resistance line-line   RL (Ω)

1.4

Inductance line-line   LL (mH)

7.5

Electrical time constant τe (ms)

5.35

Mechanical time constant τm (ms)

0.75

Reverse voltage constant Ke (V/krpm)

40

Torque constant           Kt (Nm/A)

0.662

Rotor moment of inertia   Jm (Kg·cm² )

1.36

Pole pair number

3

Maximum voltage rising du/dt (KV/μs)

8

Insulation class

F

Maximum radial force    F (N)

335

Maximum axial force  F (N)

167.5

Weight  G(Kg)

4(with brake)

Length of motor L(mm)

197±1.5(with brake)

Position feedback device

Incremental encoder 2500ppr

Cooling method

Totally enclosed, non-ventilated

Protection level

IP65 for body, shaft sealing IP54

Environmental 
conditions for 
operation

Temperature

-20centigrade degree~40centigrade degree

Humidity

Below 90% RH (No condensing)

Ambient enviroment

Away from active gas, combustible gas, oil drops and dust

Altitude

Maximum altitude 4000m, Rated power at 1000m or below, Above 1000m: Decreasing 1.5% per 100m rise

2 Drive Specifications

Model

ED430

ED430-0075-AA-K-000

Main Supply Voltage

Single-Phase AC220V±15%

Rated Power Frequency

50Hz~60Hz

Control Power Supply

DC24±10% , 2A

Digital Signal Input

DC24±10%, 10mA

Digital Signal Output

DC24±10%, 0.5A

Analog Signal Input

-10V~+10V

Rated Output Power(KW)

0.75

Energy-Consumed Braking

If the system generates an over-voltage alarm when it starts or stops sharply, add an external braking resistor to absorb the feedback energy of the motor, the minimum resistance for ED430 Series is 27W

Energy-Consumed Braking Voltage

DC385±5V

Over-Voltage Alarm Voltage

DC400±5V

Under-Voltage Alarm Voltage

DC210±5V

Dimensions mm (H×W×D) 

265X165X62

Weight

1.9Kg

Operating Temperature

0~40centigrade degree

Storage Temperature

-10~70centigrade degree

Humidity

5~85%

Contamination Level

2

Protection Level

IP20

Installation Environment

Installed in a Dust-Free, Dry, and Lockable Environment (in a Electrical Cabinet, for Example)

Installation Mode

Vertical Installation

Installation Altitude

No Power Limit Under 1000m

Pressure

86~106Kpa

Internal Programmable

An Internal Space of 16.5 KB is Provided for 256 Sequences, Which can Save a Controller on Some Occasions

External I/O

3 External Digital Outputs (24V,0.5A),the Target Position to Output or Alarm Output Function can be Implemented by Internal Programming

8 External Digital Inputs, Supporting Internal Sequence Calling Via the Input Interface and Positioning Function

(Input Delay: About 1 ms; Input Current: About 4 mA)

Analog Input

One Differential Analog Input, Implementing Control Over Motor Speed and Position by Analog Input; Input Voltage Range ± 10V, Input Delay: About 0.1 ms

Analog Output

Two Independent Analog Outputs, Capable of Monitoring the Change of Internal Object

Comparator

Four Internal Comparators, With the Comparison Results to be Used to Trigger Program Sequences

Timer

Supporting the Function of Triggering Sequences by Timer or Events

Counter

Four Groups of Internal Counters, Which can be Set to Trigger Sequences

Calculator

An Internal Calculator can be Used for Data Duplication, Addition, Subtraction, Multiplication, and Division, and Logic Operation

Internal Oscilloscope

The ECO2WIN Software Enables a User to Monitor Operation Parameters Such as Speed, Position and Current on a PC

Encoder Signal Output Function

In a Master/Slave Control Mode, the Motor Encoder Signal or Master Encoder Signal can be the Input for the Slave Signal Encoder, With a Maximum Output Frequency of 2 MHz

Master Encoder Signal Input Function

Programmable to be Pulse/Direction Signal Control, CW/CCWW Control, Electronic Gear or electronic cam control (5V signal), with a maximum input frequency of 2 MHz

Feedback Signal

Incremental A, B, Z , /A, /B, /Z Signal

RS232

9.6K Baud Rate, Supporting a Maximum of 15 Sites, and Supporting Direct Communication with a PC with the ECO2WIN Software, or Direct Communication with an eView Touch Screen or Text

RS485

38.4K Baud Rate, Supporting a Maximum of 15 Sites, and Communication Cables with a Length up to 400M

CAN BUS

Maximum Baud Rate of 1M, and Supporting a Maximum of 127 Sites

PROFIBUS DP

Maximum Baud Rate of 12M, and Supporting a Maximum of 127 Sites

 



  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: