Motor + Drive: SMH60S-0040-30AAK-3LKH+ED430-0040-AA-K-000
1 Motor Specifications
Motor series
Small inertia, flange size 60mm
Model
SMH60S-0040-30AAK-3LKH
DC link voltage UDC
300
Continuous
performanceRated power PN (W)
400
Rated torque TN (Nm)
1.27
Rated speed nN (rpm)
3000
Rated current IN (A)
3.1
Maximum torque Tm (Nm)
3.82
Maximum current Im (A)
9.3
Standstill torque TS (Nm)
1.39
Standstill current IS (A)
3.38
Resistance line-line RL (Ω)
3.52
Inductance line-line LL (mH)
7.8
Electrical time constant τe (ms)
2.22
Mechanical time constant τm (ms)
1.35
Reverse voltage constant Ke (V/krpm)
29
Torque constant Kt (Nm/A)
0.48
Rotor moment of inertia Jm (Kg·cm² )
0.51
Pole pair number
3
Maximum voltage rising du/dt (KV/μs)
8
Insulation class
F
Maximum radial force F (N)
180
Maximum axial force F (N)
90
Weight G(Kg)
1.8
Length of motor L(mm)
150
Position feedback device
Incremental encoder 2500ppr
Cooling method
Totally enclosed, non-ventilated
Protection level
IP65 for body, shaft sealing IP54
Environmental
conditions for
operationTemperature
-20centigrade degree~40centigrade degree
Humidity
Below 90% RH (No condensing)
Ambient enviroment
Away from active gas, combustible gas, oil drops and dust
Altitude
Maximum altitude 4000m, Rated power at 1000m or below, Above 1000m: Decreasing 1.5% per 100m rise
2 Drive Specifications
Model
ED430
ED430-0040-AA-K-000
Main Supply Voltage
Single-Phase AC220V±15%
Rated Power Frequency
50Hz~60Hz
Control Power Supply
DC24±10% , 2A
Digital Signal Input
DC24±10%, 10mA
Digital Signal Output
DC24±10%, 0.5A
Analog Signal Input
-10V~+10V
Rated Output Power(KW)
0.4
Energy-Consumed Braking
If the system generates an over-voltage alarm when it starts or stops sharply, add an external braking resistor to absorb the feedback energy of the motor, the minimum resistance for ED430 Series is 27W
Energy-Consumed Braking Voltage
DC385±5V
Over-Voltage Alarm Voltage
DC400±5V
Under-Voltage Alarm Voltage
DC210±5V
Dimensions mm (H×W×D)
265X165X62
Weight
1.9Kg
Operating Temperature
0~40centigrade degree
Storage Temperature
-10~70centigrade degree
Humidity
5~85%
Contamination Level
2
Protection Level
IP20
Installation Environment
Installed in a Dust-Free, Dry, and Lockable Environment (in a Electrical Cabinet, for Example)
Installation Mode
Vertical Installation
Installation Altitude
No Power Limit Under 1000m
Pressure
86~106Kpa
Internal Programmable
An Internal Space of 16.5 KB is Provided for 256 Sequences, Which can Save a Controller on Some Occasions
External I/O
3 External Digital Outputs (24V,0.5A),the Target Position to Output or Alarm Output Function can be Implemented by Internal Programming
8 External Digital Inputs, Supporting Internal Sequence Calling Via the Input Interface and Positioning Function
(Input Delay: About 1 ms; Input Current: About 4 mA)
Analog Input
One Differential Analog Input, Implementing Control Over Motor Speed and Position by Analog Input; Input Voltage Range ± 10V, Input Delay: About 0.1 ms
Analog Output
Two Independent Analog Outputs, Capable of Monitoring the Change of Internal Object
Comparator
Four Internal Comparators, With the Comparison Results to be Used to Trigger Program Sequences
Timer
Supporting the Function of Triggering Sequences by Timer or Events
Counter
Four Groups of Internal Counters, Which can be Set to Trigger Sequences
Calculator
An Internal Calculator can be Used for Data Duplication, Addition, Subtraction, Multiplication, and Division, and Logic Operation
Internal Oscilloscope
The ECO2WIN Software Enables a User to Monitor Operation Parameters Such as Speed, Position and Current on a PC
Encoder Signal Output Function
In a Master/Slave Control Mode, the Motor Encoder Signal or Master Encoder Signal can be the Input for the Slave Signal Encoder, With a Maximum Output Frequency of 2 MHz
Master Encoder Signal Input Function
Programmable to be Pulse/Direction Signal Control, CW/CCWW Control, Electronic Gear or electronic cam control (5V signal), with a maximum input frequency of 2 MHz
Feedback Signal
Incremental A, B, Z , /A, /B, /Z Signal
RS232
9.6K Baud Rate, Supporting a Maximum of 15 Sites, and Supporting Direct Communication with a PC with the ECO2WIN Software, or Direct Communication with an eView Touch Screen or Text
RS485
38.4K Baud Rate, Supporting a Maximum of 15 Sites, and Communication Cables with a Length up to 400M
CAN BUS
Maximum Baud Rate of 1M, and Supporting a Maximum of 127 Sites
PROFIBUS DP
Maximum Baud Rate of 12M, and Supporting a Maximum of 127 Sites