Product Description:
Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for information on approved
models.)
Incorporates a switch with a durable coil spring in a tough, highprecision case.
Compact and uses a single basic switch for applications where strength is required.
Models for microloads and models with operation indicators added to series.
Terminal protective cover can be switched to wire cable from either the left or right.
Sealing characteristics that meet IEC IP67 degree of protection.
Specifications:
Degree of protections
IP67 (EN60947-5-1)
Durability
Mechanical
10,000,000 operations min.
Electrical
500,000 operations min.
Operating speed
0.1 mm/s to 0.5 m/s (hinge lever models)
Operating
Mechanical
120 operations/min
frequency
Electrical
30 operations/min
Rated frequency
50/60 Hz
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
15 mΩ max. (initial value for the built-in switch when tested alone)
Dielectric
Between terminals of the same polarity
1,000 VAC, 50/60 Hz for 1 min
strength
Between each terminal and non-
2,000 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1)
current-carrying metal part
Rated insulation voltage (Ui)
150 V (EN60947-5-1)
Pollution degree (operating environment)
3 (EN60947-5-1)
Short-circuit protective device (SCPD)
10 A fuse type gI or gG (IEC60269)
Conditional short-circuit current
100 A (EN60947-5-1)
Conventional enclosed thermal current (Ithe)
5 A (EN60947-5-1)
Protection against electric shock
Class II (grounding not required with double insulation)
OFF reverse voltage
1,000 VAC max., 300 VDC max. (EN60947-5-1)
Vibration
Malfunction
10 to 55 Hz, 1.5-mm double amplitude
resistance
Shock
Destruction
1,000 m/s2 min.
resistance
Malfunction
300 m/s2 min.
Ambient operating temperature
-10°C to +80°C (with no icing)
Ambient operating humidity
35% to 95%RH
Weight
Approx. 62 to 72 g
Note:
1.The figures at the left are initial values.
2.The ratings at the left may vary depending on the model. Contact your OMRON representative for further details.
*1.The head section of the plunger type SHL-D(Q)[][] is excluded.
*2.Durability values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH.
*3.The values are for the plunger-type models.