S8JX-G05024CD Switching Power Supply NEWS8JX-G05024CD OMRON Switching Power Supply NEWProduct Description:
Flexible Selection of Reliability and Ease of Operation with the S8JX. New Models with Harmonic Current Suppression for a Broader Lineup.
Specifications:
Input specification
100 to 240 V input
Power ratings *1
15 W
35 W
Efficiency
68% min.
73% min.
Input
Voltage *2
100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC *9)
Frequency *2
50/60 Hz (47 to 450 Hz)
Current *3
100 V input
0.4 A max.
1 A max.
200 V input
0.25 A max.
0.6 A max.
Harmonic current emissions
---
Leakage
100 V input
0.5 mA max.
current *3
200 V input
1 mA max.
Inrush current
100 V input
20 A max.
(for a cold
start at 25 °C)
*3
200 V input
40 A max.
Output
Voltage adjustment range *5
- 10% to 15% (with V. ADJ) (48-V models: ± 10%)
*4
Ripple *3
2% (p-p) max.
Input variation influence
0.4% max. with AC input voltage
Load variation influence
0.8% max. (0 to 100% load, rated input voltage)
Temperature variation influence
0.05%/ ° C max. (at rated input and output)
Startup time
500 ms max. (up to 90% of output voltage at rated input and output)
Hold time *3
20 ms min.
Additional
Overload protection *6
105% to 175% of rated load current, voltage drop, intermittent, automatic reset
functions
Overvoltage protection *7
Yes
Overheat protection
No
Parallel operation
No (However, backup operation is possible; external diodes required.)
Series operation
Yes (For up to two Power Supplies; external diodes required.)
Protective circuit operation indicator
No
Other
Ambient operating temperature
Refer to the derating curve in Engineering Data on Data Sheet (with no icing or
condensation).
Storage temperature
- 25 to 65 ° C (with no icing or condensation)
Ambient operating humidity
25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength
3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA)
Insulation resistance
100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC
Vibration resistance
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
Shock resistance
150 m/s2 , 3 times each in ± X, ± Y, ± Z directions
Output indicator
Yes (Color: Green)
EMI
Conducted
Conforms to EN 55011 Group 1 Class A and based on FCC Class A *9
Emissions
Radiated Emissions
Conforms to EN 55011 Group 1 Class A *9
EMS
Electrostatic
Conforms to EN61000-4-2
Discharge
Radiated
Conforms to EN61000-4-3
Electromagnetic
Field
Electrical Fast
Conforms to EN61000-4-4
Transient/Burst
Surge
Conforms to EN61000-4-5
Conducted
Conforms to EN61000-4-6
Disturbance
Voltage Dips/
Conforms to EN61000-4-11
Short Interruptions
Approved standards *9
UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition)
cUL Listed: CSA C22.2 No.107.1
cUR: CSA C22.2 No. 60950-1
EN/VDE: EN50178 (= VDE 0160) Over voltage category III, EN 60950-1 (= VDE 0805
Teil 1) (Terminal block: Based on DIN 50274 (VDE 0660-514))
SEMI
SEMI F47-0200 (200-VAC input)
Weight *8
250 g max.
Input specification
100 to 240 V input
Power ratings *1
50 W
100 W
Efficiency
5 V Models
76% min.
76% min.
12 V Models
81% min.
81% min.
24 V Models
83% min.
83% min.
48 V Models
82% min.
83% min.
Input
Voltage *2
100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC *9)
Frequency *2
50/60 Hz (47 to 450 Hz)
Current *3
100 V input
1.4 A max.
2.5 A max.
200 V input
0.8 A max.
1.5 A max.
Harmonic current emissions
---
Leakage
100 V input
0.5 mA max.
current *3
200 V input
1 mA max.
Inrush current
100 V input
20 A max.
(for a cold
start at 25 °C)
*3
200 V input
40 A max.
Output
Voltage adjustment range *5
- 10% to 15% (with V. ADJ) (48-V models: ± 10%)
*4
Ripple *3
2% (p-p) max.
Input variation influence
0.4% max. with AC input voltage
Load variation influence
0.8% max. (0 to 100% load, rated input voltage)
Temperature variation influence
0.05%/ ° C max. (at rated input and output)
Startup time
500 ms max. (up to 90% of output voltage at rated input and output)
Hold time *3
20 ms min.
Additional
Overload protection *6
105% to 175% of rated load current, voltage drop, intermittent, automatic reset
functions
Overvoltage protection *7
Yes
Overheat protection
No
Parallel operation
No (However, backup operation is possible; external diodes required.)
Series operation
Yes (For up to two Power Supplies; external diodes required.)
Protective circuit operation indicator
No
Other
Ambient operating temperature
Refer to the derating curve in Engineering Data on Data Sheet (with no icing or
condensation).
Storage temperature
- 25 to 65 ° C (with no icing or condensation)
Ambient operating humidity
25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength
3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA)
Insulation resistance
100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC
Vibration resistance
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
Shock resistance
150 m/s2 , 3 times each in ± X, ± Y, ± Z directions
Output indicator
Yes (Color: Green)
EMI
Conducted
Conforms to EN 55011 Group 1 Class A and based on FCC Class A *9
Emissions
Radiated Emissions
Conforms to EN 55011 Group 1 Class A *9
EMS
Electrostatic
Conforms to EN61000-4-2
Discharge
Radiated
Conforms to EN61000-4-3
Electromagnetic
Field
Electrical Fast
Conforms to EN61000-4-4
Transient/Burst
Surge
Conforms to EN61000-4-5
Conducted
Conforms to EN61000-4-6
Disturbance
Voltage Dips/Short
Conforms to EN61000-4-11
Interruptions
Approved standards *9
UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition)
cUL Listed: CSA C22.2 No.107.1
cUR: CSA C22.2 No. 60950-1
EN/VDE: EN50178 (= VDE 0160) Over voltage category III, EN 60950-1 (= VDE 0805
Teil 1) (Terminal block: Based on DIN 50274 (VDE 0660-514))
SEMI
SEMI F47-0200 (200-VAC input)
Weight *8
300 g max.
550 g max.
Input specification
100/200 V switchable
100 to 240 V input
Power ratings *1
150 W at 5 V
150 W at 12 V
150 W at 24 or 48 V
Efficiency
5 V Models
78% min.
---
---
12 V Models
---
79% min.
---
24 V Models
---
---
86% min.
48 V Models
---
---
85% min.
Input
Voltage *2
Switchable between 100 to 120 VAC
100 to 240 VAC
(allowable range: 85 to 132 VAC) and
(allowable range: 85 to 264 VAC,
200 to 240 VAC (allowable range: 170
80 to 370 VDC *9)
to 264 VAC).
Frequency *2
50/60 Hz (47 to 450 Hz)
Current *3
100 V input
3.5 A max.
3.6 A max.
3.5 A max.
200 V input
2.1 A max.
2.2 A max.
2.1 A max.
Harmonic current emissions
---
Leakage
100 V input
0.5 mA max.
current *3
200 V input
1 mA max.
Inrush current
100 V input
20 A max.
(for a cold
start at 25 °C)
*3
200 V input
40 A max.
Output
Voltage adjustment range *5
- 10% to 15% (with V. ADJ) (48-V models: ± 10%)
*4
Ripple *3
2% (p-p) max.
Input variation influence
0.4% max. (with AC input voltage)
Load variation influence
0.8% max. (0 to 100% load, rated input voltage)
Temperature variation influence
0.05%/ ° C max. (at rated input and output)
Startup time
500 ms max. (up to 90% of output voltage at rated input and output)
Hold time *3
20 ms min.
Additional
Overload protection *6
105% to 175% of rated load current,
105% to 175% of rated load current,
functions
voltage drop, automatic reset
voltage drop, intermittent, automatic
reset
Overvoltage protection *7
Yes
Overheat protection
No
Parallel operation
No (However, backup operation is possible; external diodes required.)
Series operation
Yes (For up to two Power Supplies; external diodes required.)
Protective circuit operation indicator
No
Other
Ambient operating temperature
Refer to the derating curve in Engineering Data on Data Sheet (with no icing or
condensation).
Storage temperature
- 25 to 65 ° C (with no icing or condensation)
Ambient operating humidity
25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength
3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA)
Insulation resistance
100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC
Vibration resistance
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
Shock resistance
150 m/s2 , 3 times each in ± X, ± Y, ± Z directions
Output indicator
Yes (Color: Green)
EMI
Conducted
Conforms to EN 55011 Group 1 Class A and based on FCC Class A *9
Emissions
Radiated Emissions
Conforms to EN 55011 Group 1 Class A *9
EMS
Electrostatic
Conforms to EN61000-4-2
Discharge
Radiated
Conforms to EN61000-4-3
Electromagnetic
Field
Electrical Fast
Conforms to EN61000-4-4
Transient/Burst
Surge
Conforms to EN61000-4-5
Conducted
Conforms to EN61000-4-6
Disturbance
Voltage Dips/Short
Conforms to EN61000-4-11
Interruptions
Approved standards *9
UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition)
cUL Listed: CSA C22.2 No.107.1
cUR: CSA C22.2 No. 60950-1
EN/VDE: EN50178 (= VDE 0160), Over voltage category III, EN 60950-1 (= VDE 0805
Teil 1) (Terminal block: Based on DIN 50274 (VDE 0660-514))
SEMI
---
SEMI F47-0200 (200-VAC input)
Weight *8
800 g max.
700 g max.
600 g max.
*1.When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not start. Refer to Overload Protection in Data Sheet.
*2.Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning.
*3.Rated input voltage: 100 or 200 VAC at 100% load.
*4.Output characteristics: Specified at power supply output terminals.
*5.If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.
*6.For details, refer to Overload Protection in Data Sheet.
*7.To reset the protection, turn OFF the input power for seven minutes or longer and then turn it back ON.
*8.The weight indicated is for Front-mounting, Open-frame Power Supply.
*9.The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).