No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
ZE-Q22-2 Travel Switch NEWZE-Q22-2 OMRON Travel Switch NEWOMRON Travel Switch ZE-Q22-2
Product Description:
Z General-purpose Basic Switches are built into ZE, ZV, and ZV2 Switches. They provided high durability and high breaking capacity.
X Basic Switches with magnetic blowout are built into XE, XV, and XV2 Switches. DC models have also been added to the series.
Three mounting methods (side, base, and diagonal side) and many types of actuator are available.
Terminals face the front when the cover is removed for easy connection.
Switches with ground terminals have CE marking.
Approved by UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for information on approved models.)
Specifications:
Degree of protection
IP65 * 1
Durability * 2
Mechanical
Z[]: 10,000,000 operations min.
X[]: 1,000,000 operations min.
Electrical
Z[]: 500,000 operations min., for 15 A, 250 VAC resistive load
X[]: 100,000 operations min., for 10 A, 125 VDC resistive load
Operating speed
Plunger type: 0.01 mm/s to 0.5 m/s
Lever type: 0.02 mm/s to 0.5 m/s
Operating frequency
Mechanical
120 operations/min
Electrical
20 operations/min
Rated frequency
50/60 Hz
Insulation resistance
100 M Ω min. (at 500 VDC)
Contact resistance
15 m Ω max. (initial value)
Terminal temperature rise
50 ° C max.
Dielectric
Between terminals of
1,000 VAC, 50/60 Hz for 1 min
strength
the same polarity
Between current-carrying
Z[]: 2,000 VAC, 50/60 Hz for 1 min
metal part and ground
X[]: 1,500 VAC, 50/60 Hz for 1 min
Between each terminal
Z[]: 2,000 VAC, 50/60 Hz for 1 min
and non-current-carrying
X[]: 1,500 VAC, 50/60 Hz for 1 min
metal part
Vibration resistance
Malfunction
10 to 55 Hz, 1.5-mm double amplitude * 3
Shock
Destruction
1 ,000 m/s2 min.
resistance * 3
Malfunction
100 m/s2 min. * 4
50 m/s2 min. * 5
Ambient operating temperature
-10 ° C to +80 ° C (with no icing)
Ambient operating humidity
General-purpose type: 35% to 85%RH
Sealed type: 35% to 95%RH
Weight
Approx. 260 to 280 g
Note:
*1. IP65 for []-N models and IP60 for []-Q models.
*2. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments.
*3. At the operation limit positions.
*4. Only for plunger, sealed plunger, roller arm lever, and sealed roller arm lever.
*5. Only for crossroller plunger, sealed crossroller plunger, roller plunger, and sealed roller plunger..
No comment |