Your Position: Home > Transducer/Sensor > Photoelectric Sensors > Photoelectric Switch > SHL-D55 Travel Switch NEW

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

SHL-D55 Travel Switch NEW

prevnext

SHL-D55 Travel Switch NEW
  • Market price: $ 69.3
  • Shop price: $ 21.0
  • Goods click count: 287
  • Total:
  • Quantity:
Add to cart collect
  

Description

SHL-D55 OMRON Travel Switch NEW

OMRON Travel Switch SHL-D55

Product Description:

Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for information on approved

models.)

Incorporates a switch with a durable coil spring in a tough, highprecision case.

Compact and uses a single basic switch for applications where strength is required.

Models for microloads and models with operation indicators added to series.

Terminal protective cover can be switched to wire cable from either the left or right.

Sealing characteristics that meet IEC IP67 degree of protection.

Specifications:

Degree of protections

IP67 (EN60947-5-1)

Durability

Mechanical

10,000,000 operations min.

Electrical

500,000 operations min.

Operating speed

0.1 mm/s to 0.5 m/s (hinge lever models)

Operating

Mechanical

120 operations/min

frequency

Electrical

30 operations/min

Rated frequency

50/60 Hz

Insulation resistance

100 MΩ min. (at 500 VDC)

Contact resistance

15 mΩ max. (initial value for the built-in switch when tested alone)

Dielectric

Between terminals of the same polarity

1,000 VAC, 50/60 Hz for 1 min

strength

Between each terminal and non-

2,000 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1)

 

current-carrying metal part

Rated insulation voltage (Ui)

150 V (EN60947-5-1)

Pollution degree (operating environment)

3 (EN60947-5-1)

Short-circuit protective device (SCPD)

10 A fuse type gI or gG (IEC60269)

Conditional short-circuit current

100 A (EN60947-5-1)

Conventional enclosed thermal current (Ithe)

5 A (EN60947-5-1)

Protection against electric shock

Class II (grounding not required with double insulation)

OFF reverse voltage

1,000 VAC max., 300 VDC max. (EN60947-5-1)

Vibration

Malfunction

10 to 55 Hz, 1.5-mm double amplitude

resistance

Shock

Destruction

1,000 m/s2 min.

resistance

Malfunction

300 m/s2 min.

Ambient operating temperature

-10°C to +80°C (with no icing)

Ambient operating humidity

35% to 95%RH

Weight

Approx. 62 to 72 g

Note:

1.The figures at the left are initial values.

2.The ratings at the left may vary depending on the model. Contact your OMRON representative for further details.

*1.The head section of the plunger type SHL-D(Q)[][] is excluded.

*2.Durability values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH.

*3.The values are for the plunger-type models.

 

  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: