No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
D4E-1A20N Travel Switch NEWD4E-1A20N OMRON Travel Switch NEWOMRON Travel Switch D4E-1A20N
Product Description:
Flat springs with an improved lever ratio of the built-in switch ensure smooth snap action and long life expectancy.
Protection cover protects the built-in switch from dust and oil. Plunger incorporates a tough seal cap that lasts for a long time.
One touch connector eliminates need for tedious wiring operations and reduces downtime for wiring and maintenance (models with standard, easy-to-use screw terminals are also available).
Minute load model with gold cladding is optimal for electronic control.
Molded terminal types as well as molded terminal types with operating indicator lamps are available for screw terminal systems.
Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for Information on approved models.)
No difference in mounting pitch and characteristics between D4E-[]N and D4E models.
Specifications:
Degree of protection
IP67
Durability *
Mechanical
10,000,000 operations min.
Electrical
500,000 operations min. (5 A at 250 VAC, resistive load)
5,000,000 operations min. (10 mA at 24 VDC, resistive load)
Operating speed
0.1 mm/sec to 0.5 m/sec
Operating frequency
Mechanical: 120 operations/min
Electrical: 30 operations/min
Rated frequency
50/60 Hz
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
15 mΩ max. (initial value for the built-in switch when tested alone)
Dielectric strength
Between terminals of same polarity
1,000 VAC, 50/60 Hz for 1 min
Between each terminal and non-
1,500 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1)
current-carrying metal part
Rated insulation voltage (Ui)
250V
Pollution degree (operating environment)
3 (EN60947-5-1)
Short-circuit protective device (SCPD)
10 A fuse (type gG or gI, IEC60269 approved)
Conditional short-circuit current
100 A (EN60947-5-1)
Conventional enclosed thermal current (Ithe)
5 A (EN60947-5-1)
Protection against electric shock
Class II (grounding not required with double insulation)
Vibration resistance
Malfunction
10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Destruction
1,000 m/s2 min.
Malfunction
300 m/s2 min.
Ambient operating temperature
-10°C to +80°C (with no icing)
Ambient operating humidity
35% to 95%RH
Weight
Approx. 86 g (in case of roller plunger)
Note:
1.The above values are initial values.
2.The above ratings may vary depending on the model. Contact your OMRON representative for further details