D4C-3220 OMRON Travel Switch NEW

OMRON Travel Switch D4C-3220   

Product Description:

Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for information on approved models.)

Sealing characteristics that meet IEC IP67 degree of protection.

Triple-sealed construction:

Plunger section sealed via nitrile rubber packing seal and diaphragm; switch section sealed via nitrile rubber cap; cable entrance sealed via encapsulating material.

Cable lengths of 3 and 5 m available on standard models. Models also available with UL and CSA-certified cables.

Multiple mounting possible with Switches with Plungers.

Models with red LED indicators added to series for easy confirmation of operation. (Set by default to light for non-operation.)

VCTF oil-resistant cables with CE marking. (Applicable only to standard models.) 

Specifications:

Degree of protection

IP67

Durability *1

Mechanical *3

10,000,000 operations min.

Electrical *2

200,000 operations min. (5 A at 125 VAC, resistive load)

Operating speed

0.1 mm/s to 0.5 m/s (in case of plunger)

1 mm/s to 1 m/s (in case of roller lever)

Operating

Mechanical

120 operations/min

frequency

Electrical

30 operations/min

Rated frequency

50/60 Hz

Insulation resistance

100 M Ω min. (at 500 VDC)

Contact resistance (initial)

250 m Ω max. (initial value with 2-m VCTF cable)

300 m Ω max. (initial value with 3-m VCTF cable)

400 m Ω max. (initial value with 5-m VCTF cable)

Dielectric

Between terminals of the same polarity

1,000 VAC, 50/60 Hz for 1 min

strength

Between current-carrying metal part

1,500 VAC, 50/60 Hz for 1 min

 

and ground

Uimp: 2.5 kV (EN60947-5-1)

 

Between each terminal and non-current-

1,500 VAC, 50/60 Hz for 1 min

 

carrying metal part,

Uimp: 2.5 kV (EN60947-5-1)

Rated insulation voltage (Ui)

300 V (EN60947-5-1) *5

Pollution degree (operating environment)

3 (EN60947-5-1)

Short-circuit protective device (SCPD)

10 A fuse type gI or gG (IEC60269)

Conditional short-circuit current

100 A (EN60947-5-1)

Conventional enclosed thermal current (I the)

5 A, 4 A, 0.5 A (EN60947-5-1)

Protection against electric shock

Class I (with grounding wire) *6

Vibration

Malfunction

10 to 55 Hz, 1.5-mm double amplitude *4

resistance

Shock

Destruction

1,000 m/s2 min.

resistance

Malfunction

500 m/s2 min. *4

Ambient operating temperature

-10 ° C to +70 ° C (with no icing)

Ambient operating humidity

35% to 95%RH

Weight (D4C-1202)

With 3-m VCTF cable: 360 g

With 5-m VCTF cable: 540 g

 

Note:The above figures are initial values.

*1.The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments.

*2.Pre-wired Models: 1,000,000 operations min. (DC specifications, switching current: 0.1 A)

*3.Outdoor specifications: 500,000 operations min.

*4.Excluding Plastic Rods.

*5.Pre-wired models: 250 V

*6.Pre-wired models: class III

 

  