OMRON Travel Switch D4C-1224
Product Description:
Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and diaphragm; switch section sealed via nitrile rubber cap; cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models. Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy confirmation of operation. (Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking. (Applicable only to standard models.)
Specifications:
Degree of protection
IP67
Durability *1
Mechanical *3
10,000,000 operations min.
Electrical *2
200,000 operations min. (5 A at 125 VAC, resistive load)
Operating speed
0.1 mm/s to 0.5 m/s (in case of plunger)
1 mm/s to 1 m/s (in case of roller lever)
Operating
Mechanical
120 operations/min
frequency
Electrical
30 operations/min
Rated frequency
50/60 Hz
Insulation resistance
100 M Ω min. (at 500 VDC)
Contact resistance (initial)
250 m Ω max. (initial value with 2-m VCTF cable)
300 m Ω max. (initial value with 3-m VCTF cable)
400 m Ω max. (initial value with 5-m VCTF cable)
Dielectric
Between terminals of the same polarity
1,000 VAC, 50/60 Hz for 1 min
strength
Between current-carrying metal part
1,500 VAC, 50/60 Hz for 1 min
and ground
Uimp: 2.5 kV (EN60947-5-1)
Between each terminal and non-current-
1,500 VAC, 50/60 Hz for 1 min
carrying metal part,
Uimp: 2.5 kV (EN60947-5-1)
Rated insulation voltage (Ui)
300 V (EN60947-5-1) *5
Pollution degree (operating environment)
3 (EN60947-5-1)
Short-circuit protective device (SCPD)
10 A fuse type gI or gG (IEC60269)
Conditional short-circuit current
100 A (EN60947-5-1)
Conventional enclosed thermal current (I the)
5 A, 4 A, 0.5 A (EN60947-5-1)
Protection against electric shock
Class I (with grounding wire) *6
Vibration
Malfunction
10 to 55 Hz, 1.5-mm double amplitude *4
resistance
Shock
Destruction
1,000 m/s2 min.
resistance
Malfunction
500 m/s2 min. *4
Ambient operating temperature
-10 ° C to +70 ° C (with no icing)
Ambient operating humidity
35% to 95%RH
Weight (D4C-1202)
With 3-m VCTF cable: 360 g
With 5-m VCTF cable: 540 g
Note:The above figures are initial values.
*1.The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments.
*2.Pre-wired Models: 1,000,000 operations min. (DC specifications, switching current: 0.1 A)
*3.Outdoor specifications: 500,000 operations min.
*4.Excluding Plastic Rods.
*5.Pre-wired models: 250 V
*6.Pre-wired models: class III
No comment |