Product Description:
Only 6 mm thick yet provides a sensing distance of 3 mm (TL-W3MC1).
Aluminum die-cast models also available.
Specifications:
Model
TL-W1R5MC1
TL-W3MC[]
TL-W5MC[]
TL-W5E1
TL-W20ME1
TL-W5E2
TL-W20ME2
TL-W5F1
TL-W5F2
Sensing distance
1.5 mm ±10%
3 mm ±10%
5 mm ±10%
20 mm ±10%
Set distance
0 to 1.2 mm
0 to 2.4 mm
0 to 4 mm
0 to 16 mm
Differential travel
10% max. of sensing distance
1% to 15% of sensing
distance
Detectable object
Ferrous metal
(The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.)
Standard sensing object
Iron,
Iron,
Iron,
Iron,
8 × 8 × 1 mm
12 × 12 × 1 mm
18 × 18 × 1 mm
50 × 50 × 1 mm
Response frequency
1 kHz min.
600 Hz min.
500 Hz min.
300 Hz min.
40 Hz min.
Power supply voltage
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
12 to 24 VDC (10 to
12 to 24 VDC
(operating voltage
30 VDC), ripple (p-p):
(10 to 30 VDC),
range)
20% max.
ripple (p-p): 10% max.
Current consumption
15 mA max. at 24 VDC (no-load)
10 mA max.
15 mA max. at 24
8 mA at 12 VDC,
VDC (no-load)
15 mA at 24 VDC
Control
Load
NPN open collector
NPN open collector
200 mA
100 mA max.
output
current
100 mA max. at 30 VDC max.
50 mA max. at 12 VDC
at 12 VDC
(30 VDC max.)
200 mA max.
100 mA max. at 24 VDC
at 24 VDC
(30 VDC max.)
Residual
1 V max. (under load current of 100
1 V max. (under load
2 V max. (under load
1 V max. (under load
voltage
mA with cable length of 2 m)
current of 50 mA with
current of 200 mA with
current of 200 mA with
cable length of 2 m)
cable length of 2 m)
cable length of 2 m)
Indicators
Detection indicator (red)
Operation mode
NO
C1 Models: NO
E1/F1 Models: NO
(with sensing object
C2/B2 Models: NC
E2/F2 Models: NC
approaching)
Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.
Protection circuits
Reverse polarity protection, Surge suppressor
Ambient temperature
Operating/Storage: -25 to 70°C (with no icing or condensation) *
range
Ambient humidity range
Operating/Storage: 35% to 95% (with no condensation)
Temperature influence
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence
±2.5% max. of sensing distance at
±2.5% max. of sensing
±2.5% max. of sensing distance at rated voltage
rated voltage in the rated voltage
distance at rated voltage
in the rated voltage ±10% range
±10% range
in the rated voltage
±20% range
Insulation resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2 3 times each in X, Y, and Z directions
Destruction: 500 m/s2
10 times each in X, Y,
and Z directions
Degree of protection
IEC 60529 IP67, in-house standards: oil-resistant *
Connection method
Pre-wired Models (Standard cable length: 2 m)
Weight (packed state)
Approx. 30 g
Approx. 45 g
Approx. 70 g
Approx. 180 g
Materials
Case
Heat-resistant ABS
Aluminum die-cast
Heat-resistant ABS
Sensing
Heat-resistant ABS
surface
Accessories
Mounting Bracket,
Instruction manual
Instruction manual
For environments that require oil resistance, the upper limit of the ambient operating temperature range is 40°C.
No comment |