No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
E2K-L26MC1 Proximity Switch NEWE2K-L26MC1 OMRON Proximity Switch NEWOMRON Proximity Switch E2K-L26MC1
Product Description:
Mount to bypass pipes.
Fit a wide range of pipe diameters: 8 to 11 mm or 12 to 26 mm
Built-in Amplifiers to save space.
Specifications:
Model
E2K-L13MC1
E2K-L26MC1
Applicable pipes
Materials
Non-metal
Size
Diameter
8 to 11 mm
12 to 26 mm
Thickness
1 mm max.
1.5 mm max.
Detectable object
Liquid *
Repeat accuracy
±0.2 mm max.
Differential travel
0.6 to 5 mm
0.3 to 3 mm
(Reference value, varies with
pipe size and liquid.)
Power supply voltage
12 to 24 VDC (10.8 to 30 VDC), ripple (p-p): 10% max.
(operating voltage range)
Current consumption
12 mA max.
Control output
Load current
100 mA max.
Residual voltage
1 V max. (Load current: 100 mA, Cable length: 2 m)
Sensing liquid position
Indented mark position (For details, refer to Datasheet)
Indicators
Detection indicator (orange)
Ambient temperature range
Operating: 0 to 55°C (with no icing or condensation), Storage: -10 to 65°C (with no icing or condensation)
Ambient humidity range
Operating/Storage: 25% to 85% (with no condensation)
Temperature influence
±4 mm of detection level at 23°C in the temperature range of 0 to 55°C
(with pure water or 20% saline solution)
(±6 mm for E2K-L13MC1 with pure water and a pipe diameter of 8 mm)
Voltage influence
±0.5 mm of detection level at the rated voltage in rated voltage ±10% range
Insulation resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2 3 times each in X, Y, and Z directions
Degree of protection
IP66 (IEC)
Connection method
Pre-wired Models (Standard cable length: 2 m)
Weight (packed state)
Approx. 70 g
Materials
Case, Cover
Heat-resistant ABS
Cable clamp
NBR
Accessories
Two bands, Four slip-proof tubes, Instruction manual
*Stable detection will not be possible in the following cases. Confirm detection capability with the Sensor installed before actual application.
1. If the specific inductive capacity or the specific electric conductivity of the liquid is too low, the liquid position may not be detected since this sensor is a capacitive sensor.
2. If the quantity of liquid is too low or the change in quantity is too low in comparison to the change in liquid level because the pipe is too thin or the walls of the pipe are too thick.
3. If there is a viscous film on the inner pipe wall, large quantities of foam or air bubbles, or excessive buildup of dirt on the inner pipe wall