No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
TL-Q5MC1-Z Proximity Sensor NEWTL-Q5MC1-Z Omron Proximity Sensor NEWProduct Description and Specifications:
Technical characteristics
• TL-N / TL-Q / TL-G is the inductive proximity sensor
• Sensing distance: 5 ... 20 mm
• The sensor type is not covered
• Frequency response: DC 40 ... AC 10Hz or 500 Hz max.
• Supply voltage: 12-24 VDC
• Connectivity: Wireless connectivity is available, DC 2 - wire or 3-wire DC or 2-wire AC
• Control output: current 0 ... 100mA
• outputs: NPN / PNP, NO / NC
Type
Unshielded
Sensing method
Inductive type
Sensing distance
5 mm -10% to +10%
Setting distance
0 to 4 mm
Differential distance
10% Max. of sensing distance
Sensing object
Ferrous metal (Sensitivity lowers with non-ferrous metals.)
Standard sensing object
Iron 15*15*1mm
Response frequency
DC: 500 Hz (average)
Response time
2 ms Max.
Power supply voltage
12 to 24 VDC (ripple(p-p) :10% Max.)
Operating voltage range
10 to 30 VDC
Current consumption
10 mA Max. (at 24VDC)
Control output (Output type)
PNP open collector output
Control output (Switching capacity)
0 to 50 mA (at 30VDC)
Control output (Residual voltage)
(DC) 1 V Max. ?under load current with cable length of 2m?
Indicator
Detection indicator(red)
Operation mode
NO
Protective circuit
Surge suppressor
Power supply reverse polarity protectionStandard or Different frequency
Standard
Ambient temperature
Operating: -25 to 70 CEL
Storage: -25 to 70 CEL
(with no icing or condensation)Ambient humidity
Operating: 35 to 95 %RH
Storage: 35 to 95 %RH
(with no condensation)Temperature influence
+-20% Max. of sensing distance in temperature range of -25 to +70CEL
(As the basis for sensing distance of 23CEL)Voltage influence
+-2.5% Max. of sensing distance in rated voltage range +-10%. (As the basis for sensing distance at standard power voltage)
Insulation resistance
5 M OHM Min. at 500VDC between charged parts and the case
Dielectric strength
500 VAC 50/60 Hz for 1 minute between charged parts and the case
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
200m/s2 for 10 times each in X, Y, and Z directions
Degree of protection
IEC60529: IP67
Applicable standard (EC Directive (Low Voltage Directive))
EN60947-1
EN60947-5-2Applicable standard (EC Directive (EMC Directive))
EMI: EN60947-5-2
Emission Enclosure: CISPR11 Group 1 class A
EMS: EN60947-5-2
Immunity ESD: IEC61000-4-2
Immunity RF-interference: IEC61000-4-3
Immunity Conducted Disturbance: IEC61000-4-6
Immunity Burst: IEC61000-4-4
CE marking: EquippedApplicable standard (CCC mark)
Not equipped
Connection method
Pre-wired models (Cable length: 2 m)
Weight (Packed state)
approx. 60 g
Material (case)
Heat-resistant ABS resin
Material (sensing surface)
Heat-resistant ABS resin
Accessories
Not equipped