E3C-LDA11 Omron Amplifier Units NEW

Product Description:

• All three beam types provide ample long-distance detection of 1,000 mm for Diffuse Reflective Models.

• Coaxial Retroreflective Models provide detection performance equivalent to through-beam sensors, simplifying Sensor installation.

• Industry-first variable focal point and optical axis alignment mechanisms. Optimize for workpieces and improve inspection quality.

• Drive the laser with an Amplifier the same size as a Digital Fiber Amplifier..

Specifications:

Power supply voltage

12 to 24 VDC -10% to 10% (ripple(p-p) :10% Max.)

Current consumption

45mA DC Max.

Power consumption

1080mW DC Max. (at 24 VDC)

Control output (Output type)

NPN open collector output

Control output (Load current)

0 to 50 mA

Control output (Residual voltage)

(DC) 1 V Max. (Load current 50mA Max.)

Operation mode

Light-ON/Dark-ON selectable

Load power supply voltage

26.4 VDC Max.

Protective circuit

Surge suppressor

Output short-cut protection

Power supply reverse polarity protection

Mutual interference prevention

Sensitivity setting

Teaching method

Self-diagnostic output

Equipped

Timer function

ON-delay 1 ms to 5 s

OFF-delay 1 ms to 5 s

One-shot delay 1 ms to 5 s

Function

Twin-output, area output, differential operation

Ambient temperature

Operating: -25 to 55 CEL (Groups of 1 to 2 Sensors)

Operating: -25 to 50 CEL (Groups of 3 to 10 Sensors)

Operating: -25 to 45 CEL (Groups of 11 to 16 Sensors)

Storage: -30 to 70 CEL

(with no icing or condensation)

Ambient humidity

Operating: 35 to 85 %RH

Storage: 35 to 85 %RH

(with no condensation)

Insulation resistance

20 M OHM Min. at 500 VDC between charged parts and the case

Dielectric strength

1000 VAC at 50/60 Hz for 1 minute between charged parts and the case

Vibration resistance

10 to 150 Hz, 0.7-mm double amplitude for 1.5 hours each in X, Y, and Z directions

Shock resistance

500m/s2 for 3 times each in X, Y, and Z directions

Degree of protection

IEC60529: IP50

Applicable standard (EC Directive (Low Voltage Directive))

EN60947-5-2

Applicable standard (EC Directive (EMC Directive))

EMI: EN60947-5-2

Emission Enclosure: EN55011 Group 1 class A

EMS: EN60947-5-2

Immunity ESD: IEC61000-4-2

Immunity RF-interference: IEC61000-4-3

Immunity Burst: IEC61000-4-4

CE marking: Equipped

Connection method

Pre-wired models (Cable length: 2 m)

Indicator

Operation indicator(orange), Digital display

Weight (packed state)

approx. 100 g

Material (case)

PBT

Material (cover)

Polycarbonate

Amplifier unit/sensor head of combination