No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
E3C-JC4P Amplifier Units NEWE3C-JC4P Omron Amplifier Units NEWProduct Description:
Thin, Compact Head Saves Space and Mounts Closely. Built-in Interference Protection Provided.
• Input indicator on the Sensor Unit simplifies settings.
Specifications:
Item
Model
E3C-A
E3C-C
E3C-JC4P
E3C-GE4
Power supply voltage
100 to 240 VAC±10%, 50/60 Hz
12 to 24 VDC±10%, ripple (p-p): 1 V max.
Power (current) consumption
3 W max.
50 mA max.
Control output
Transistor output
Load power supply voltage: 24 VDC max., load current: 80 mA max., voltage output type, output current: 1 to 4 mA (residual voltage: 1.2 V max.) Light-ON/Dark-ON switch selectable
Load power supply voltage: 24 VDC max., load current: 100 mA max., NPN open collector output type (residual voltage: 1 V max.) Light-ON/Dark-ON switch selectable
Load power supply voltage: 24 VDC max., load current: 80 mA max., voltage output type, output current: 1 to 4 mA (residual voltage: 0.7 V max.) Light-ON/Dark-ON cable connection selectable
Relay output
220 VAC 1 A cosφ=1 (resistive load) SPDT contact only
--
External synchronous input
--
H = 6 to 30 V L = 0 to 2 V When L, turns OFF the control output forcibly.
--
Timer function
--
ON/OFF, oneshot delay (selectable): 1 or 10 s max.
OFF-delay 0/40 ms (switch selectable)
--
Ambient temperature range
Operating: −10° to 55°C, Storage: −25° to 70°C (with no icing or condensation)
Ambient humidity range
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)
Insulation resistance
20 MΩ min. at 500 VDC
Dielectric strength
500 VAC at 50/60 Hz for 1 minute
Vibration resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 300 ms2 three times in each of X, Y and Z directions
Degree of protection
IEC IP20 (limited to indoor use)
IEC IP60 (limited to indoor use)
IEC IP20 (limited to indoor use)
Protection
Reverse polarity protection, output short-circuit protection, mutual interference prevention
Response time
No contact
Operate or reset: 1 ms max./2 ms max. each (switch selectable)
Operate or reset: 1 ms max.
Operate or reset: 1 ms max./2 ms max. each (switch selectable)
Relay
Operate or reset: 20 ms max.
--
Connection method
Terminal block
Terminal block input cable pullout (standard cable length: 2 m)
Terminal block
Weight (packed state)
Approx. 200 g
Approx. 80 g
Approx. 15 g
Material
Case
ABS
Polycarbonate
Mounting Brackets
Stainless steel
--
Iron
--
Accessories
Connection Socket (PF113A) Instruction manual
Mounting Bracket, Adjustment screwdriver, Caution label, Instruction manual
Instruction manual
No comment |