No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
E2FQ-X10D1 Chemical-resistant Proximity Sensor NEWE2FQ-X10D1 Omron Chemical-resistant Proximity Sensor NEWProduct Description:
• Housing and mounting are made of Fluororesin resistant to chemicals.
• Maximum sensing distance: 10 mm.
Specifications:
Model
E2FQ-X2E1
E2FQ-X2D1E2FQ-X5E1
E2FQ-X5D1
E2FQ-X5Y1E2FQ-X10E1
E2FQ-X10D1
E2FQ-X10Y1Item
Sensing distance
2 mm ±10%
5 mm ±10%
10 mm ±10%
Set distance
0 to 1.6 mm
0 to 4 mm
0 to 8 mm
Differential travel
E1/Y1 Models: 10% max. of sensing distance, D1 Models: 20% max. of sensing distance
Detectable object
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 3.)
Standard sensing object
Iron, 12 × 12 × 1 mm
Iron, 18 × 18 × 1 mm
Iron, 30 × 30 × 1 mm
Response frequency *
E1 Models: 1.5 kHz D1 Models: 800 Hz
E1 Models: 600 Hz D1 Models: 500 Hz
E1 Models: 400 Hz D1 Models: 300 Hz
Y1 Models: 25 Hz
Power supply voltage (operating voltage range)
E1 Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. Y1 Models: 24 to 240 VAC (20 to 264 VAC), 50/60 Hz D1 Models: 12 to 24 VDC (10 to 36 VDC), ripple (p-p): 20% max.
Current consumption
E1 Models: 17 mA max.
Leakage current
D1 Models: 0.8 mA max., Y1 Models: 1.7 mA max. (at 200 VAC)
Control output
Load current
E1 Models: 200 mA max., D1 Models: 5 to 100 mA, Y1 Models: 5 to 300 mA
Residual voltage
E1 Models: 2 V max. (Load current: 200 mA, Cable length: 2 m) Y1 Models: Refer to Engineering Data on page 3. D1 Models: 3 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators
E Models: Detection indicator (red), Y Models: Operation indicator (red), D Models: Operation indicator (red), Setting indicator (green) (NO only)
Operation mode (with sensing object approaching)
E1/D1/Y1 Models: NO (Refer to the timing charts under I/O Circuit Diagrams on page 5 for details.)
Protection circuits
E1 Models: Load short-circuit protection, Reverse polarity protection, Surge suppressor, D1/Y1 Models: Surge suppressor
Ambient temperature range
Operating/Storage: −25 to 70°C (with no icing or condensation)
Ambient humidity range
Operating/Storage: 35% to 95% (with no condensation)
Temperature influence
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
Voltage influence
E1 Models: ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range D1 Models: ±2.5% max. of sensing distance at rated voltage in the rated voltage ±20% range Y1 Models: ±1% max. of sensing distance at rated voltage in the rated voltage ±10% range
Insulation resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
E1/D1 Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case Y Models: 4,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2 10 times each in X, Y, and Z directions
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection
IEC 60529 IP67, in-house standards: oil-resistant
Connection method
Pre-wired Models (Cable length: 2 m)
Weight (packed state)
Approx. 70 g
Approx. 130 g
Approx. 170 g
Materials
Case
Fluororesin
Sensing surface
Clamping nuts
Toothed washer
Zinc-plated iron
Cable
Vinyl chloride
Accessories
Instruction manual
Note:
The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
No comment |