Your Position: Home > Control System > PLC > Delta PLC > DVP60EC00R3 Delta PLC 100-240VAC 36DI 24DO relay output Standard Original brand new

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

DVP60EC00R3 Delta PLC 100-240VAC 36DI 24DO relay output Standard Original brand new

prevnext

DVP60EC00R3 Delta PLC 100-240VAC 36DI 24DO relay output Standard Original brand new
  • Market price: $ 679.8
  • Shop price: $ 206.0
  • Goods click count: 345
  • Total:
  • Quantity:
Add to cart collect
  

Description

DVP60EC00R3 Delta PLC 100-240VAC 36DI 24DO relay output Standard Original brand new


Introduction

EC3 series is the most economical solution for sequential control and communication monitoring and can operate independently, allowing the user to achieve stand-alone monitor, e.g. monitoring phototransistor coupler, proximity switch, optical sensor, indicator and illumination switch. Through serial ports, EC3 is able to connect to control devices such as PLC, frequency inverter and temperature controller, which can be said to be a programmable application solution that is cost-friendly and highly reliable.

Specifications

Model

Item

10EC

00_3

14 EC

00_3

16 EC

00_3

20 EC

00_3

24 EC

00_3

30 EC

00_3

32 EC

00_3

40 EC

00_3

48 EC

00_3

60 EC

00_3

Power supply voltage

100 ~ 240VAC (-15% ~ 10%), 50/60Hz + -5%

Operation

DVP-EC3 starts to run when the power supply rises to 95 ~ 100V AC and

stops when the power supply drops to 70V AC. It continues to run for 10ms

after the power supply is cut off.

Power supply fuse

2A/250VAC

Power consumption

12VA

15.6VA

22.5VA

DC24V current output

200mA

300mA

400mA

Power supply protection

DC24V output short circuit protection

Voltage withstand

1,500VAC (Primary-secondary), 1,500VAC (Primary-PE), 500VAC

(Secondary-PE)

Insulation resistance

> 5MΩ at 500VDC (between all I/O points and earth)

Noise immunity

ESD (IEC 61131-2, IEC 61000-4-2): 8kV Air Discharge

EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2kV, Digital I/O: 1kV, Analog

& Communication I/O: 1kV

RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m

Grounding

The diameter of grounding wire shall not be less than that of L, N terminal of

the power supply. (When many PLCs are in use at the same time, please

make sure every PLC is properly grounded.)

Operation/storage

Operation: 0 °C ~55 °C (temperature), 50~95% (humidity), pollution degree 2

Storage: -25 °C ~70 °C (temperature), 5~95% (humidity)

Agency approvals

UL508

European community EMC Directive 89/336/EEC and Low Voltage Directive

73/23/EEC

Vibration/shock immunity

International standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/ IEC61131-2 &

IEC 68-2-27 (TEST Ea)

RS-485 Port

No

Yes

Weight (g)

R

205

210

220

310

322

325

340

380

540

560

T

192

195

198

285

288

290

295

340

505

510

             

  