No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
VTF18-4P1240 SICK Photoelectric switch NEWVTF18-4P1240 SICK Photoelectric switch NEWProduct Description:
Focused optics, which provide background blanking and an excellent scanning reliability
2 scanning distance options :SD 1 = 50 mm, SD 2 = 100
Optionally VT 18-3 in 3-line model or VT 18-4 with light/dark control line
Many other options
Specifications:
Housing
Straight
Angled, 90°
VTF 18 Scanning distance 50 mm
Scanning distance, max. typical1)
0...50 mm
Operating distance1)
0...45 mm
Light spot diameter
Approx. 3 mm at a distance of 25 mm
Angle of dispersion of sender
Focused, focus 25 mm
Sensitivity, adjustable (optional)
Potentiometer 270°
VTF 18 Scanning distance 100 mm
Scanning distance, max. typical1)
3...100 mm
Operating distance1)
3...90 mm
Light spot diameter
Approx. 3 mm at a distance of 50 mm
Angle of dispersion of sender
Focused, focus 50 mm
Sensitivity, adjustable (optional)
Potentiometer 270°
Light source2), light type
LED, infrared light
Supply voltage VS
10...30 V DC3)
Ripple4)
±10 %
Current consumption5)
≤ 30 mA
Switching outputs (optional)
PNP/NPN
Switching mode
Q, dark-switching
Q, light-switching
via control wire6)
Q, light-/dark-switching
+VS=light-switching
0 V = dark-switching
Output current IA max.
100 mA
Response time7)
≤ 2 ms
Max. switching frequency8)
250/s
Connection types
cable 2 m9)
PVC, 3 x 0.14 mm2, l3.1 mm
PVC, 4 x 0.14 mm2, l5 mm
plug
4-pin, M12
VDE protection class10)
?
Circuit protection11)
A, B, C, D
Enclosure rating
IP 67
Ambient temperature TA
– 25 °C...+ 70 °C
Weight
metal housing Approx. 120 g
plastic housing
Approx. 100 g
Housing material
metal housing
Nickel-plated brass;PBT/PC
plastic housing
PBT/PC
optic
PMMA
1) Object with 90 % reflectance (referred to standard white DIN 5033)
2) Average service life 100,000 h at TA = + 25 °C
3) Limit values
4) Must be within VS tolerances
5) Without load
6) Control wire open: NPN: light-switching PNP: dark-switching
7) With resistive load
8) With light/dark ratio 1:1
9) Do not bend below 0 °C
10) Reference voltage 50 V DC
11) A = Vs connections reverse-polarity protected
B = Inputs/outputs reverse-polarity protected
C = Interference suppression
D = Outputs overcurrent and shortcircuit protected
No comment |