No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
MQ10-60APS-KT0 SICK Magnetic Proximity sensor NEWProduct Description:
Installation, can be flush or flush in metal
Sensing distance of up to 60mm
PNP or NPN output
High switching frequency
Short-circuit protection (pulsed)
Plastic shell
Cable or plug
Degree of protection IP67
LED status indicators
Technical specifications?
Sensing range Sn | 5 ... 60 mm |
Magnetic alignment | Axial |
Electrical configuration | DC 3-wire |
Supply voltage Vs | 10 ... 30 V DC |
Ripple Upp | ≤ 10 %1? |
Voltage drop Ud | ?1.5 V2) |
Power consumption | ?10mA3) |
Continuous current Ia | ≤ 300mA |
Time delay before availability tv | ≤2 ms |
Hysteresis H, of sr | 1... 10 % |
Repeatability R | ?1% (Ub and Ta constant)4? |
Temperature drift, of sr | ± 10 % |
EMC | According to EN 60947-5-2 |
Switching output | PNP |
NPN | |
Output function | Normally open |
Connection type | Connector, M8, 3-pin |
Cable, PVC/PUR, 2 m | |
Enclosure rating | IP 675? |
Max. switching frequency | 5000 Hz |
Dimensions | 10.3 x 16 x 28 mm6) |
10.3 x 16 x 37 mm6) | |
Wire-break protection | √ |
Short-circuit protection | √7) |
Reverse polarity protection | √ |
Power-up pulse suppression | √ |
Shock/vibration stress | 30 g, 11 ms/10 ... 55 Hz, 1 mm |
Ambient temperature operation | –25 °C ... +75 °C |
Housing material | plastic |
Tightening torque | 0.8 Nm |
Notes?
1) Of Ub
2) At Ia max
3) Without load
4) Of sr
5) According to EN 60529
6) Width x height x depth
7) (pulsed)
MQ10-60APS-KT0 SICK Magnetic Proximity sensor NEWProduct Description:
Installation, can be flush or flush in metal
Sensing distance of up to 60mm
PNP or NPN output
High switching frequency
Short-circuit protection (pulsed)
Plastic shell
Cable or plug
Degree of protection IP67
LED status indicatorsTechnical specifications?
Sensing range Sn
5 ... 60 mm
Magnetic alignment
Axial
Electrical configuration
DC 3-wire
Supply voltage Vs
10 ... 30 V DC
Ripple Upp
≤ 10 %1?
Voltage drop Ud
?1.5 V2)
Power consumption
?10mA3)
Continuous current Ia
≤ 300mA
Time delay before availability tv
≤2 ms
Hysteresis H, of sr
1... 10 %
Repeatability R
?1% (Ub and Ta constant)4?
Temperature drift, of sr
± 10 %
EMC
According to EN 60947-5-2
Switching output
PNP
NPN
Output function
Normally open
Connection type
Connector, M8, 3-pin
Cable, PVC/PUR, 2 m
Enclosure rating
IP 675?
Max. switching frequency
5000 Hz
Dimensions
10.3 x 16 x 28 mm6)
10.3 x 16 x 37 mm6)
Wire-break protection
√
Short-circuit protection
√7)
Reverse polarity protection
√
Power-up pulse suppression
√
Shock/vibration stress
30 g, 11 ms/10 ... 55 Hz, 1 mm
Ambient temperature operation
–25 °C ... +75 °C
Housing material
plastic
Tightening torque
0.8 Nm
Notes?
1) Of Ub
2) At Ia max
3) Without load
4) Of sr
5) According to EN 60529
6) Width x height x depth
7) (pulsed)
No comment |