No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
IQ40-20NPP-KK0 SICK Inductive Proximity sensor NEWDescription?
Installation, flush in metal
Can change in five surface sensing direction
AC operating voltage range
Normally open / normally closed function
Plastic shell
Degree of protection 68
Terminal block connection
LED status indicators
Specification?
Sensing range Sn | 15 mm |
20 mm | |
Electrical configuration | DC 3-wire |
Supply voltage Vs | DC 10 ... 36 V |
Voltage drop Ud | ≤ 2.5V1? |
Power consumption | ≤ 15 Ma2? |
Continuous current Ia | ≤ 250 mA |
Time delay before availability tv | ≤ 4ms |
Hysteresis H, of sr | 1…15% |
Repeatability R | ?10 % (Ub and Ta constant)3? |
Temperature drift, of sr | ± 10 % |
EMC | According to EN 60947-5-2 |
Switching output | PNP |
Output function | Programmable |
Installation | flush |
Non-flush | |
Connection type | Cable gland, Terminal, M20 x 1.5 |
Enclosure rating | IP 674? |
Max. switching frequency | 300 Hz |
Dimensions | 40 x 40 x 121 mm5? |
Short-circuit protection | √ 6? |
Reverse polarity protection | √ |
Power-up pulse suppression | √ |
Shock/vibration stress | 30 g, 11 ms/10 ... 55 Hz, 1 mm |
Ambient temperature Ta | –25 °C ... +80 °C |
Housing material | plastic |
Notes:
1) at Ia max and Ub 24 V
2) without load
3) of sr
4) according to EN 60529
5) Width x height x depth
6) (pulsed)
IQ40-20NPP-KK0 SICK Inductive Proximity sensor NEWDescription?
Installation, flush in metal
Can change in five surface sensing direction
AC operating voltage range
Normally open / normally closed function
Plastic shell
Degree of protection 68
Terminal block connection
LED status indicatorsSpecification?
Sensing range Sn
15 mm
20 mm
Electrical configuration
DC 3-wire
Supply voltage Vs
DC 10 ... 36 V
Voltage drop Ud
≤ 2.5V1?
Power consumption
≤ 15 Ma2?
Continuous current Ia
≤ 250 mA
Time delay before availability tv
≤ 4ms
Hysteresis H, of sr
1…15%
Repeatability R
?10 % (Ub and Ta constant)3?
Temperature drift, of sr
± 10 %
EMC
According to EN 60947-5-2
Switching output
PNP
Output function
Programmable
Installation
flush
Non-flush
Connection type
Cable gland, Terminal, M20 x 1.5
Enclosure rating
IP 674?
Max. switching frequency
300 Hz
Dimensions
40 x 40 x 121 mm5?
Short-circuit protection
√ 6?
Reverse polarity protection
√
Power-up pulse suppression
√
Shock/vibration stress
30 g, 11 ms/10 ... 55 Hz, 1 mm
Ambient temperature Ta
–25 °C ... +80 °C
Housing material
plastic
Notes:
1) at Ia max and Ub 24 V
2) without load
3) of sr
4) according to EN 60529
5) Width x height x depth
6) (pulsed)
No comment |