Why buy from us?
We offer competitive prices and quality services!
Ask a Question About This Product
- Stock: In Stock
- Model: H7EC-N
- Weight: 0.06kg
2. Shipping options include DHL, UPS, FedEx, and EMS.
3. Estimated delivery time for express shipping via DHL, UPS, FedEx, or EMS generally ranges from 3 to 10 business days, depending on the destination country.
4. Please verify your address thoroughly when placing your order.
5. Important for buyers: You are responsible for any tariffs on accessories. To potentially avoid these tariffs, you may choose EMS express shipping.
6. The shipping service is responsible for any accidents, delays, or other issues that may arise.
Returns:
We offer a 14-day return policy. If you wish to return an item, please contact us within 14 days and ensure that the package remains unopened. The buyer is responsible for the shipping costs for both the return and the initial delivery, as well as any applicable customs fees. Once we receive and inspect the product, we will process your refund within 24 hours.
For any quality issues that arise during normal use within the warranty period, we will repair the item free of charge. The buyer is responsible for the return shipping cost, while our company will cover the cost of re-shipping the repaired item.
OMRON Counter H7EC-N
Product Description:
48*24 mm , Totalizing Counter , 8 Digits , No-Voltage Input
Specifications:
Function | Total Counter |
Rated supply voltage | Not required External supply voltage(powered by built-in battery) |
Counter (Count range) | 0 to 99999999 |
Counter (Max. counting speed) | 30 Hz/1 kHz(switching) |
Minimum counting input signal width: 16.7 ms(ON/OFF ratio: 1:1)/0.5 ms(ON/OFF ratio: 1:1) | |
Counter (Input mode) | Increment |
Counter (Reset system) | External and manual reset |
Input signal | Count input ,Reset |
Input method | No-voltage input |
No-voltage input (No-contact input) | Short-circuit (ON) impedance: 10 kOhm max. |
Residual voltage: 0.5 V max. (Actual performance 1.0 V) | |
Open circuit impedance: 750 kOhm min. | |
Minimum input signal width | External reset: 20 ms |
Display method | 7-segment transmissive LCD |
Digit | 8 digit |
Character height | Count value: 8.6 mm (Black) |
Zero suppression: Equipped | |
Prescaling function | Not provided |
Key protection | Key protect Switch |
Teaching function | Not provided |
Batch counting function | Not provided |
Communications | Not provided |
Memory backup | Battery |
Battery life | For 7 years min. (with continuous input at 25CEL) |
Surrounding air temperature | Operating: -10 to +55 CEL (With no icing or condensation) |
Storage: -25 to +65 CEL (With no icing or condensation) | |
Ambient humidity | Operating: 25% to 85% |
Storage: 25% to 85% | |
Characteristics | |
Insulation resistance | 100 MOhm min. (at 500 VDC) |
Between current-carrying terminals and exposed non-current-carrying metal parts | |
Dielectric withstand voltage | Between current-carrying terminals and exposed non-current-carrying metal parts: 1000 VAC 50/60 Hz for 1 min |
Impulse withstand voltage | Between current-carrying terminal and exposed non-current -carrying metal parts: 4.5 kV |
Noise immunity | Between count input terminals: +-500 V |
Between reset terminals: +-500 V | |
Square-wave noise by noise simulator (Pulse width: 100 ns/1 us, 1-ns rise) | |
Static immunity | 8 kV (malfunction) |
Vibration resistance (Destruction) | 10 to 55 Hz with 0.375 mm single amplitude for two hours each in three directions |
Vibration resistance (Malfunction) | 10 to 55 Hz with 0.15 mm single amplitude for ten minutes each in three directions |
Shock resistance (Destruction) | 300 m/s2 three times each in six directions |
Shock resistance (Malfunction) | 200 m/s2 three times each in six directions |
Degree of protection | Case front: IP66, NEMA 4 (indoors), and UL Type 4X (indoors)(when using the Y92S-32 Waterproof Packing and Y92F-30 Flush Mounting Adapter) |
Terminal block: IP20 | |
Applicable standard (UL) | Standard No.: UL863 |
File number: E67871 | |
Applicable standard (CSA) | Standard No.: CSA C22.2 No.14 |
File number: LR22310 | |
Applicable standard (VDE) | VDE0106/P100 |
Applicable standard (LR) | Approved |
Applicable standard (EC Directive (Machinery Directive)) | EN61010-1 |
Applicable standard (EC Directive (Low Voltage Directive)) | EN61010-1 |
Applicable standard (EC Directive (EMC Directive)) | EMI: EN61326 |
Emission Enclosure: EN55011 Group 1 Class B | |
EMS: EN61326 | |
Immunity ESD: EN61000-4-2 (4 kV contact discharge (level 2);8 kV air discharge (level 3)) | |
Radiated electromagnetic field immunity: EN61000-4-3 (10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3);10 V/m (Pulse-modulated, 900 MHz +-5 MHz) (level 3)) | |
Immunity Conducted Disturbance: EN61000-4-6 (10 V (0.15 to 80 MHz) (level 3)) | |
Immunity Burst: EN61000-4-4 (2 kV power-line;2 kV I/O signal-line) | |
Mounting method | Flush mounting |
External connection method | Screw terminals |
Case color | Light gray (Munsell 5Y7/1) |
Attachment | Flush mounting adapter, Waterproof rubber packing, Shock Prevention Cover |
Weight | Approx. 60 g |