Why buy from us?
We offer competitive prices and quality services!
Ask a Question About This Product
- Stock: In Stock
- Model: H7CX-AUD1-N
- Weight: 0.13kg
2. Shipping options include DHL, UPS, FedEx, and EMS.
3. Estimated delivery time for express shipping via DHL, UPS, FedEx, or EMS generally ranges from 3 to 10 business days, depending on the destination country.
4. Please verify your address thoroughly when placing your order.
5. Important for buyers: You are responsible for any tariffs on accessories. To potentially avoid these tariffs, you may choose EMS express shipping.
6. The shipping service is responsible for any accidents, delays, or other issues that may arise.
Returns:
We offer a 14-day return policy. If you wish to return an item, please contact us within 14 days and ensure that the package remains unopened. The buyer is responsible for the shipping costs for both the return and the initial delivery, as well as any applicable customs fees. Once we receive and inspect the product, we will process your refund within 24 hours.
For any quality issues that arise during normal use within the warranty period, we will repair the item free of charge. The buyer is responsible for the return shipping cost, while our company will cover the cost of re-shipping the repaired item.
OMRON Counter H7CX-AUD1-N
Product Description:
DIN 48 × 48 mm Multifunction Preset Counter with a Bright, Easy-to-view, Negative Transmissive LCD
Specifications:
H7CX-A114[]-N | H7CX-AW[]-N/-AU[]-N | |||
H7CX-A11[]-N | ||||
H7CX-A4[]-N | ||||
H7CX-A[]-N | ||||
H7CX-A4W[]-N | ||||
No tachometer | Selectable from independent measurements for 1 or 2 inputs, differential input for 2 inputs, | |||
functionality | absolute ratio for 2 inputs, and error ratio for 2 inputs. | |||
| Periodic measurement | Pulse width measurement | ||
| ||||
| 30 Hz | 1-input mode: 10 kHz | 30 Hz | 1-input mode: 10 kHz (minimum |
| (minimum | (minimum pulse width: 0.05 ms) | (minimum | pulse width: 0.05 ms) |
| pulse width: | Other modes: 5 kHz (minimum | pulse width: | Other modes: 5 kHz (minimum |
| 16.7 ms) | pulse width: 0.1 ms) | 16.7 ms) | pulse width: 0.1 ms) |
| --- | --- | 30 ms *1 | 1-input mode: 0.2 ms |
| Other modes: 0.4 ms * | |||
| 0.01 to | 1-input mode: 0.01 to 10 kHz, | 0.030 to | 1-input mode: 0.0002 to 99999 s |
| 30.00 Hz | Other modes: 0.01 to 5 kHz | 999999 s | Other modes: 0.0004 to 99999 s |
| 200 ms min. | 200 ms min. or continuous | Continuous (minimum interval of 10 ms) | |
| selectable (minimum interval | |||
| of 10 ms) | |||
| ±0.1% FS ±1 digit max. (at 23 ±5°C) | |||
| Input mode: | |||
| Not 2-input independent measurement: HI-LO, AREA, HI-HI, LO-LO | |||
| 2-input independent measurement: HI-HI, LO-LO | |||
| 0.1 to 999.9s | |||
| 0.0 to 99.9s | |||
| Simple averaging/moving averaging selectable, Processing: OFF, 2, 4, 8, or 16 times | |||
| Minimum input signal width: 20 ms | |||
Characteristics |
|
|
Insulation resistance | 100 MΩ min. (at 500 VDC) between current-carrying terminals and exposed non-current-carrying metal | |
parts, and between non-continuous contacts | ||
Dielectric strength | 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts | |
2,000 VAC, 50/60 Hz for 1 min between power supply and input circuit for all models except H7CX-[]D[] (1,000 VAC for 24 VAC/12 to 24 VDC) | ||
1,000 VAC (for H7CX-[]SD[]), 50/60 Hz for 1 min between control output, power supply, and input circuit (2,000 VAC for models other than H7CX-[]SD[]) | ||
1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts | ||
Impulse withstand voltage | 3.0 kV between power terminals (1.0 kV for models with 24 VAC/12 to 24 VDC or 12 to 24 VDC) | |
4.5 kV between current-carrying terminals and exposed non-current-carrying metal parts (1.5 kV for models with 24 VAC/12 to 24 VDC or 12 to 24 VDC) | ||
Noise immunity | ±1.5 kV between power terminals (±480 V for models with 12 to 24 VDC) ±600 V between input terminals Square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) | |
Static immunity | Malfunction: 8 kV Destruction: 15 kV | |
Vibration | Destruction | 10 to 55 Hz with 0.75-mm single amplitude each in three directions for 2 h each |
resistance | Malfunction | 10 to 55 Hz with 0.35-mm single amplitude each in three directions for 10 min each |
Shock | Destruction | 300 m/s2 each in three directions |
re-sistance | Malfunction | 100 m/s2 each in three directions |
Life expectancy | Mechanical: 10,000,000 operations min. | |
Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load, ambient temperature condition: 23°C)* | ||
Weight | Approx. 130 g (Counter only) | |