No comment |
H7CX-A4WSD OMRON Counter NEWOMRON Counter H7CX-A4WSD
Product Description:
DIN 48 × 48 mm Multifunction Preset Counter with a Bright, Easy-to-view, Negative Transmissive LCD
Specifications:
H7CX-A114[]-N
H7CX-AW[]-N/-AU[]-N
H7CX-A11[]-N
H7CX-A4[]-N
H7CX-A[]-N
H7CX-A4W[]-N
No tachometer
Selectable from independent measurements for 1 or 2 inputs, differential input for 2 inputs,
functionality
absolute ratio for 2 inputs, and error ratio for 2 inputs.
Periodic measurement
Pulse width measurement
30 Hz
1-input mode: 10 kHz
30 Hz
1-input mode: 10 kHz (minimum
(minimum
(minimum pulse width: 0.05 ms)
(minimum
pulse width: 0.05 ms)
pulse width:
Other modes: 5 kHz (minimum
pulse width:
Other modes: 5 kHz (minimum
16.7 ms)
pulse width: 0.1 ms)
16.7 ms)
pulse width: 0.1 ms)
---
---
30 ms *1
1-input mode: 0.2 ms
Other modes: 0.4 ms *
0.01 to
1-input mode: 0.01 to 10 kHz,
0.030 to
1-input mode: 0.0002 to 99999 s
30.00 Hz
Other modes: 0.01 to 5 kHz
999999 s
Other modes: 0.0004 to 99999 s
200 ms min.
200 ms min. or continuous
Continuous (minimum interval of 10 ms)
selectable (minimum interval
of 10 ms)
±0.1% FS ±1 digit max. (at 23 ±5°C)
Input mode:
Not 2-input independent measurement: HI-LO, AREA, HI-HI, LO-LO
2-input independent measurement: HI-HI, LO-LO
0.1 to 999.9s
0.0 to 99.9s
Simple averaging/moving averaging selectable, Processing: OFF, 2, 4, 8, or 16 times
Minimum input signal width: 20 ms
Characteristics
Insulation resistance
100 MΩ min. (at 500 VDC) between current-carrying terminals and exposed non-current-carrying metal
parts, and between non-continuous contacts
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts
2,000 VAC, 50/60 Hz for 1 min between power supply and input circuit for all models except H7CX-[]D[] (1,000 VAC for 24 VAC/12 to 24 VDC)
1,000 VAC (for H7CX-[]SD[]), 50/60 Hz for 1 min between control output, power supply, and input circuit (2,000 VAC for models other than H7CX-[]SD[])
1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts
Impulse withstand voltage
3.0 kV between power terminals (1.0 kV for models with 24 VAC/12 to 24 VDC or 12 to 24 VDC)
4.5 kV between current-carrying terminals and exposed non-current-carrying metal parts (1.5 kV for models with 24 VAC/12 to 24 VDC or 12 to 24 VDC)
Noise immunity
±1.5 kV between power terminals (±480 V for models with 12 to 24 VDC) ±600 V between input terminals Square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Static immunity
Malfunction: 8 kV Destruction: 15 kV
Vibration
Destruction
10 to 55 Hz with 0.75-mm single amplitude each in three directions for 2 h each
resistance
Malfunction
10 to 55 Hz with 0.35-mm single amplitude each in three directions for 10 min each
Shock
Destruction
300 m/s2 each in three directions
re-sistance
Malfunction
100 m/s2 each in three directions
Life expectancy
Mechanical: 10,000,000 operations min.
Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load, ambient temperature condition: 23°C)*
Weight
Approx. 130 g (Counter only)
No comment |