No comment |
H7BX-A AC100-240V OMRON Counter NEWOMRON Counter H7BX-A AC100-240V
Product Description:
Highly visible display with backlit transmissive LCD.
Selectable display color (red/green) enables checking output status at a distance.
Easy operation with a key for each digit.
Perform all basic settings with a DIP switch.
Provides a total and preset counter, batch counter, dual counter, and tachometer (See note.).
Wide range of inputs accepted for NPN/PNP inputs (multi-inputs) and 2-wire DC sensors.
Complies with UL, CSA, and CE marking.
Degree of protection: IP54 equivalent (front section only).
Note:The functions that can be selected depend on the model.
Specifications:
Model
H7BX-A/AD1
H7BX-AW/AWD1
Type
Preset counter
Preset counter/tachometer
Supported configurations
1-stage preset counter, total and preset counter
1-stage preset counter,
(See note 1.) (selectable)
2-stage preset counter,
total and preset counter (See note 1.),
batch counter, dual counter, tachometer (selectable)
Ratings
Power supply voltage
100 to 240 VAC (50/60 Hz)
(See note 2.)
24 VAC (50/60 Hz)/12 to 24 VDC (ripple 20% max.)
Operating voltage range
85% to 110% of rated supply voltage (90% to 110% at 12 VDC)
Power consumption
H7BX-A/AW: 9.6 VA max. (100 to 240 VAC)
H7BX-AD1/AWD1: 8 VA max. (24 VAC), 5.3 W max. (12 to 24 VDC)
Mounting method
Flush mounting
External connections
Screw terminals
Degree of protection
IP54 (front section only)
Input signals
CP1, CP2, reset 1, reset 2, key protection
Counter
Max. counting speed
30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), setting for both CP1 and CP2
Input modes
Increment, decrement, command (UP/DOWN A), individual (UP/DOWN B), quadrature (UP/DOWN C)
Output modes
N, F, C, R, K-1, P, Q, A, K-2, D, L
N, F, C, R, K-1, P, Q, A, K-2, D, L, H
One-shot output time
0.01 to 99.99 s
Reset input
External reset (minimum reset input signal width: 1 ms or 20 ms selectable), manual reset, and automatic reset (internal according to C, R, P, and Q mode operation)
Tachometer
Pulse measurement
---
Periodic measurement
method
(Sampling period: 200 ms)
Max. counting speed
---
30 Hz or 10 kHz (selectable)
Measuring ranges
---
30 Hz: 0.01 to 30.00 Hz
10 kHz: 0.01 Hz to 10 kHz
Measuring accuracy
---
±0.1% FS ±1 digit max. (at 23±5 ° C)
Output modes
---
Upper and lower limits, area, upper limit, lower limit
Auto-zero time
---
0.1 to 99.9 s
Startup time
---
0.0 to 99.9 s
Average processing
---
OFF/2/4/8 times
Prescaling function
Yes (0.001 to 99.999)
Decimal point adjustment
Yes (rightmost 3 digits)
Sensor waiting time
290 ms max.
(Control output is turned OFF and no input is accepted during sensor waiting time.)
Key protection input
Response speed: Approx. 1 s
No-voltage NPN input (fixed)
Short-circuit (ON) impedance: 1 k Ω max. (Leakage current at 0 Ω: Approx. 12 mA)
Short-circuit (ON) residual voltage: 3 V max.
Open (OFF) impedance: 100 kΩ min.
Input method
No-voltage NPN input or voltage PNP input (selectable)
(except key protection input)
No-voltage input
Short-circuit (ON) impedance: 1 kΩ max. (Leakage current at 0 Ω: Approx. 12 mA)
Short-circuit (ON) residual voltage: 3 V max.
Open (OFF) impedance: 100 kΩ min.
Voltage input
High level: 4.5 to 30 VDC
Low level: 0 to 2 VDC
Input resistance: Approx. 4.7 kΩ
External power supply
12 VDC (±10%), 100 mA (For details, refer to External Power Supply on Datasheet.)
Control output
Contact output: 3 A at 250 VDC/30 VDC, resistive load (cos Φ = 1)
Minimum applied load: 10 mA at 5 VDC (Failure level: P, reference value)
Transistor output: 100 mA max. at 30 VDC max.
Residual voltage: 1.5 VDC max. (approx. 1 V)
Leakage current: 0.1 mA max.
Display (See note 3.)
Backlit 7-segment negative transmissive LCD
Character Heights
PV: 13.5 mm (red/green)
SV: 9 mm (green)
Digits
6 digits
6 digits
- 99,999 to 999,999
Counter: - 99,999 to 999,999
(5 digits negative and 6 digits positive)
(5 digits negative and 6 digits positive)
Tachometer: 0 to 999,999 (6 digits)
Memory backup
EEPROM (Overwrites: 100,000 min.), Data storage: 10 years min.
Ambient operating temperature
- 10 to 55 ° C (with no icing)
Ambient storage temperature
- 25 to 65 ° C (with no icing)
Ambient operating humidity
25 to 85 ° C (with no condensation)
Case color
Black (N1.5)
Accessories
Two flush-mounting adapters, terminal cover
Two flush-mounting adapters,
terminal cover,
DIP switch setting stickers
Note:
1.The total and preset counter functions as a 1-stage preset counter and total counter.
2.Do not use an inverter output for the power supply.
3.Displayed only when the power is ON. Not displayed when the power is OFF.
No comment |