H7AN-R6DM AC100-240 OMRON Counter NEW

OMRON Counter H7AN-R6DM AC100-240        

Product Description:

72*72 mm , Preset Counter , 2 Digits , With Digital Display

Specifications:

Function

1 Stage Preset Counter

Preset stages

1 stage

Rated supply voltage

100 to 240 VAC 50/60 Hz

Operating voltage range

85% to 110% of rated supply voltage

Power consumption

Approx. 10 VA (at 100 VAC)

External power supply

12 VDC+-10% 80 mA(permissible ripple: 5%(p-p) max.)

Counter (Count range)

0 to 99

Counter (Max. counting speed)

30 Hz

Minimum counting input signal width: 16.7 ms (ON/OFF ratio: 1:1)

Counter (Input mode)

Increment or decrement (switchable)

Counter (Output modes)

N, F, C, R, K, P, Q

Counter (One-shot time)

0.1 to 1 s variable

Counter (Reset system)

External, manual, automatic and power reset

Input signal

CP1 ,CP2 ,Reset

Input method

Voltage input

No-voltage input (Contact input)

Use a contact which can adequately switch 2.5 mA at 12 V.

Voltage input

Hight level: 5 to 30 VDC

Low level: 0 to 2 VDC

Input resistance: Approx. 4.7 kOhm

Minimum input signal width

External reset: 20 ms

Manual reset: 20 ms

Automatic reset: 100 to 1000ms(C, R, P and Q mode)

Power reset: 500 ms

Control output (Contact output)

Output type: SPDT

Switching capacity: 3 A at 250 VAC/30 VDC, resistive load (cos phi=1)

Minimum applicable load: 10 mA at 5 VDC (failure level:P reference value)

Control output (Solid-state output)

Output type: Transistor output(NPN open collector)

Output resistance: 1.5 kOhm

Switchig capacity: 30 VDC max. 100mA max.

Display method

7-segment with LED display

Digit

2 digit

Character height

Count value: 10 mm (Red)

Zero suppression: Not equipped

Prescaling function

Not provided

Key protection

Not provided

Teaching function

Not provided

Batch counting function

Not provided

Communications

Not provided

Memory backup

Not provided

Surrounding air temperature

Operating: -10 to +55 CEL (With no icing or condensation)

Storage: -25 to +65 CEL (With no icing or condensation)

Ambient humidity

Operating: 35% to 85%

Storage: 35% to 85%

Characteristics

Insulation resistance

100 MOhm min. (at 500 VDC)

Between current-carrying terminals and exposed non-current-carrying metal parts / Between non-continuous contacts

Dielectric withstand voltage

Between current-carrying terminals and exposed non-current-carrying metal parts: 2000 VAC 50/60 Hz for 1 min

Between non-continuous contacts: 750 VAC 50/60 Hz for 1 min

Impulse withstand voltage

Between power terminals: 6.0 kV

Between current-carrying terminal and exposed non-current -carrying metal parts: 6.0 kV

Noise immunity

Between power terminals: +-2k V

Between input terminals: +-500 V

Square-wave noise by noise simulator (Pulse width: 100 ns/1 us, 1-ns rise)

Static immunity

+-8 kV (malfunction), +-15 kV (destruction)

Vibration resistance (Destruction)

10 to 55 Hz with 0.375 mm single amplitude for two hours each in three directions

Vibration resistance (Malfunction)

10 to 55 Hz with 0.25 mm single amplitude for ten minutes each in three directions

Shock resistance (Destruction)

300 m/s2 three times each in six directions

Shock resistance (Malfunction)

100 m/s2 two times each in six directions

Mechanical Life expectancy

10,000,000 operations min.

Electrical Life expectancy

100,000 operations min. (3 A at 250 VAC, resistive load)

Degree of protection

Case front: JEM IP30

Applicable standard (UL)

Standard No.: UL508

File number: E41515

Applicable standard (CSA)

Standard No.: CSA C22.2 No.14

File number: LR22310

Mounting method

Flush mounting

External connection method

Screw terminals

Case color

Light gray (Munsell 5Y7/1)

Attachment

Mounting bracket 2

Weight

Approx. 360 g

 

 

  