Why buy from us?
We offer competitive prices and quality services!
Ask a Question About This Product
- Stock: In Stock
- Model: H7AN-4DM
- Weight: 0.36kg
2. Shipping options include DHL, UPS, FedEx, and EMS.
3. Estimated delivery time for express shipping via DHL, UPS, FedEx, or EMS generally ranges from 3 to 10 business days, depending on the destination country.
4. Please verify your address thoroughly when placing your order.
5. Important for buyers: You are responsible for any tariffs on accessories. To potentially avoid these tariffs, you may choose EMS express shipping.
6. The shipping service is responsible for any accidents, delays, or other issues that may arise.
Returns:
We offer a 14-day return policy. If you wish to return an item, please contact us within 14 days and ensure that the package remains unopened. The buyer is responsible for the shipping costs for both the return and the initial delivery, as well as any applicable customs fees. Once we receive and inspect the product, we will process your refund within 24 hours.
For any quality issues that arise during normal use within the warranty period, we will repair the item free of charge. The buyer is responsible for the return shipping cost, while our company will cover the cost of re-shipping the repaired item.
OMRON Counter H7AN-4DM AC100-240V
Product Description:
72*72 mm , Preset Counter , 2 Digits , With Digital Display
Specifications:
Function | 1 Stage Preset Counter |
Preset stages | 1 stage |
Rated supply voltage | 100 to 240 VAC 50/60 Hz |
Operating voltage range | 85% to 110% of rated supply voltage |
Power consumption | Approx. 10 VA (at 100 VAC) |
External power supply | 12 VDC+-10% 80 mA(permissible ripple: 5%(p-p) max.) |
Counter (Count range) | 0 to 99 |
Counter (Max. counting speed) | 30 Hz |
Minimum counting input signal width: 16.7 ms (ON/OFF ratio: 1:1) | |
Counter (Input mode) | Increment or decrement (switchable) |
Counter (Output modes) | N, F, C, R, K, P, Q |
Counter (One-shot time) | 0.1 to 1 s variable |
Counter (Reset system) | External, manual, automatic and power reset |
Input signal | CP1 ,CP2 ,Reset |
Input method | Voltage input |
No-voltage input (Contact input) | Use a contact which can adequately switch 2.5 mA at 12 V. |
Voltage input | Hight level: 5 to 30 VDC |
Low level: 0 to 2 VDC | |
Input resistance: Approx. 4.7 kOhm | |
Minimum input signal width | External reset: 20 ms |
Manual reset: 20 ms | |
Automatic reset: 100 to 1000ms(C, R, P and Q mode) | |
Power reset: 500 ms | |
Control output (Contact output) | Output type: SPDT |
Switching capacity: 3 A at 250 VAC/30 VDC, resistive load (cos phi=1) | |
Minimum applicable load: 10 mA at 5 VDC (failure level:P reference value) | |
Control output (Solid-state output) | Output type: Transistor output(NPN open collector) |
Output resistance: 1.5 kOhm | |
Switchig capacity: 30 VDC max. 100mA max. | |
Display method | 7-segment with LED display |
Digit | 2 digit |
Character height | Count value: 10 mm (Red) |
Zero suppression: Not equipped | |
Prescaling function | Not provided |
Key protection | Not provided |
Teaching function | Not provided |
Batch counting function | Not provided |
Communications | Not provided |
Memory backup | Not provided |
Surrounding air temperature | Operating: -10 to +55 CEL (With no icing or condensation) |
Storage: -25 to +65 CEL (With no icing or condensation) | |
Ambient humidity | Operating: 35% to 85% |
Storage: 35% to 85% | |
Characteristics | |
Insulation resistance | 100 MOhm min. (at 500 VDC) |
Between current-carrying terminals and exposed non-current-carrying metal parts / Between non-continuous contacts | |
Dielectric withstand voltage | Between current-carrying terminals and exposed non-current-carrying metal parts: 2000 VAC 50/60 Hz for 1 min |
Between non-continuous contacts: 750 VAC 50/60 Hz for 1 min | |
Impulse withstand voltage | Between power terminals: 6.0 kV |
Between current-carrying terminal and exposed non-current -carrying metal parts: 6.0 kV | |
Noise immunity | Between power terminals: +-2k V |
Between input terminals: +-500 V | |
Square-wave noise by noise simulator (Pulse width: 100 ns/1 us, 1-ns rise) | |
Static immunity | +-8 kV (malfunction), +-15 kV (destruction) |
Vibration resistance (Destruction) | 10 to 55 Hz with 0.375 mm single amplitude for two hours each in three directions |
Vibration resistance (Malfunction) | 10 to 55 Hz with 0.25 mm single amplitude for ten minutes each in three directions |
Shock resistance (Destruction) | 300 m/s2 three times each in six directions |
Shock resistance (Malfunction) | 100 m/s2 two times each in six directions |
Mechanical Life expectancy | 10,000,000 operations min. |
Electrical Life expectancy | 100,000 operations min. (3 A at 250 VAC, resistive load) |
Degree of protection | Case front: JEM IP30 |
Applicable standard (UL) | Standard No.: UL508 |
File number: E41515 | |
Applicable standard (CSA) | Standard No.: CSA C22.2 No.14 |
File number: LR22310 | |
Mounting method | Flush mounting |
External connection method | Screw terminals |
Case color | Light gray (Munsell 5Y7/1) |
Attachment | Mounting bracket 2 |
Weight | Approx. 360 g |