Your Position: Home > Control System > PLC > Delta PLC > DVP04TC-H2 Delta PLC 4 point 0.1 degree resolution Analog Module Original brand new

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

DVP04TC-H2 Delta PLC 4 point 0.1 degree resolution Analog Module Original brand new

prevnext

DVP04TC-H2 Delta PLC 4 point 0.1 degree resolution Analog Module Original brand new
  • Market price: $ 503.2
  • Shop price: $ 152.5
  • Goods click count: 269
  • Total:
  • Quantity:
Add to cart collect
  

Description

DVP04TC-H2 Delta PLC 4 point 0.1 degree resolution Analog Module Original brand new

Features

DVP04TC-H2 is able to receive 4 points 0~150mV voltage input of thermocouple temperature sensors (J-type, K-type, R-type, S-type, T-type, E-type, N-type) and convert them into 24-bit digital signals. Besides, through FROM/TO instructions in DVP-EH2 MPU program, the data in DVP04TC-H2 can be read or written. There are 49 16-bit control registers (CR) in it. DVP04TC-H2 displays temperatures in Celsius and Fahrenheit (resolution: 0.1°F).

Specification

Temperature

measurement module 

Explanation 

Power supply voltage 

24VDC (20.4VDC ~ 28.8VDC) (-15% ~ +20%)

Analog output channel

4 channels/module

Applicable sensor types

J-type, K-type, R-type, S-type, T-type, E-type, N-type Floating thermocouple sensor, 0~150mV voltage input.

Range of input temp.

See the table in section Temperature / Digital Curve

Range of digital conversion

See the table in section Temperature / Digital Curve

Resolution

24 bits (0.1°C/0.1°F)

Overall accuracy

+ - 0.6% when in full scale within the range of 0 ~ 55°C, 32 ~ 131°F

Response time

200ms × the number of channels

Isolation

Isolation between digital circuits and analog circuits. Isolation between channels.

500VDC between digital circuits and Ground

500VDC between analog circuits and Ground

500VDC between analog circuits and digital circuits

500VDC between 24VDC and Ground

Digital data format

15 significant bits out of 16 bits are available; in 2’s complement

Average function

Yes; available for setting up in CR#2 ~ CR#5; range: K1 ~ K100

Self-diagnosis

Upper and lower bound detection/channel

Communication mode (RS-485)

ASCII/RTU mode. Communication speed: 4,800 / 9,600 / 19,200 /

38,400 / 57,600 / 115,200 bps. ASCII data format: 7-bit, even bit, 1

stop bit (7, E, 1). RTU data format: 8-bit, even bit, 1 stop bit (8, E, 1).

RS-485 cannot be used when connected to PLC MPU.

When connected to

DVP-PLC MPU in series

The modules are numbered from 0 to 7 automatically by their distance from MPU. No. 0 is the closest to MPU and No. 7 is the furthest. Maximum 8 modules are allowed to connect to MPU and will not occupy any digital I/O points.

Max. rated power consumption

24VDC (20.4VDC ~ 28.8VDC) (-15% ~ +20%), 2.5W supplied by external power.

Operation/storage

1. Operation: 0°C~ 55°C (Temperature), 50 ~ 95% (Humidity), pollution degree 2

2. Storage: -25°C~ 70°C (Temperature), 5 ~ 95%(Humidity)

Vibration/shock immunity

Standard: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)