No comment |
>
Control System >
PLC >
Siemens PLC >
6ES7314-6BG03-0AB0 SIEMENS CPU Module New6ES7314-6BG03-0AB0 SIEMENS CPU Module NewSIEMENS CPU Module 6ES7314-6BG03-0AB0
Product Description:
SIMATIC S7-300, CPU 314C-2 PTP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED INTERFACE RS485, INTEGRATED 24V DC POWER SUPPLY, 96 KBYTE WORKING MEMORY, FRONT CONNECTOR (2 X 40PIN) AND MICRO MEMORY CARD REQUIRED.
Features:
General information
Hardware product version
01
Firmware version
V2.6
Engineering with
Programming package
STEP 7 V5.3 SP2 or higher with HW update
Supply voltage
24 V DC
Yes
permissible range, lower limit (DC)
20.4 V
permissible range, upper limit (DC)
28.8 V
External protection for supply cables (recommendation)
Miniature circuit breaker, type C; min 2 A; miniature circuit breaker type B, min. 4 A
Load voltage L+
Rated value (DC)
24 V
permissible range, lower limit (DC)
20.4 V
permissible range, upper limit (DC)
28.8 V
Digital inputs
Load voltage L+
Rated value (DC)
24 V
Reverse polarity protection
Yes
Digital outputs
Load voltage L+
Rated value (DC)
24 V
Reverse polarity protection
No
Analog outputs
Load voltage L+
Rated value (DC)
24 V
Reverse polarity protection
Yes
Input current
Current consumption (rated value)
800 mA
Current consumption (in no-load operation), typ.
150 mA
Inrush current, typ.
11 A
I²t
0.7 A²·s
from supply voltage L+, max.
800 mA
Digital inputs
from load voltage L+ (without load), max.
70 mA
Digital outputs
from load voltage L+, max.
100 mA
Power losses
Power loss, typ.
14 W
Memory
Work memory
integrated
96 kbyte
expandable
No
Load memory
pluggable (MMC)
Yes
pluggable (MMC), max.
8 Mbyte
Data management on MMC (after last programming), min.
10 a
Backup
present
Yes; Guaranteed by MMC (maintenance-free)
without battery
Yes; Program and data
CPU processing times
for bit operations, min.
0.1 µs
for bit operations, max.
0.2 µs
for word operations, min.
0.2 µs
for fixed point arithmetic, min.
2 µs
for floating point arithmetic, min.
3 µs
CPU-blocks
Number of blocks (total)
1024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB
Number, max.
511; Number range: 1 to 511
Size, max.
16 kbyte
FB
Number, max.
1024; Number range: 0 to 2047
Size, max.
16 kbyte
FC
Number, max.
1024; Number range: 0 to 2047
Size, max.
16 kbyte
OB
Size, max.
16 kbyte; see instruction list
Number of free cycle OBs
1; OB 1
Number of time alarm OBs
1; OB 10
Number of delay alarm OBs
1; OB 20
Number of time interrupt OBs
1; OB 35
Number of process alarm OBs
1; OB 40
Number of startup OBs
1; OB 100
Number of asynchronous error OBs
4; OB 80, 82, 85, 87
Number of synchronous error OBs
2; OB 121, 122
Nesting depth
per priority class
8
additional within an error OB
4
Counters, timers and their retentivity
S7 counter
Number
256
of which retentive without battery
adjustable
Yes
lower limit
0
upper limit
255
preset
8
Retentivity
adjustable
Yes
lower limit
0
upper limit
255
preset
8
Counting range
lower limit
0
upper limit
999
IEC counter
present
Yes
Type
SFB
Number
Unlimited (limited only by RAM capacity)
S7 times
Number
256
of which retentive without battery
adjustable
Yes
lower limit
0
upper limit
255
Retentivity
adjustable
Yes
lower limit
0
upper limit
255
preset
No retentivity
Time range
lower limit
10 ms
upper limit
9990 s
IEC timer
present
Yes
Type
SFB
Number
Unlimited (limited only by RAM capacity)
Data areas and their retentivity
retentive data area, total
All, max. 64 KB
Flag
Number, max.
256 byte
Retentivity available
Yes; MB 0 to MB 255
Retentivity preset
MB 0 to MB 15
Number of clock memories
8; 1 memory byte
Data blocks
Number, max.
511; Number range: 1 to 511
Size, max.
16 kbyte
Retentivity adjustable
Yes; via non-retain property on DB
Retentivity preset
Yes
Local data
per priority class, max.
510 byte
Address area
I/O address area
Inputs
1 kbyte
Outputs
1 kbyte
of which, distributed
Inputs
none
Outputs
none
Process image
Inputs
128 byte
Outputs
128 byte
Default addresses of the integrated channels
Digital inputs
124,0 to 126,7
Digital outputs
124.0 to 125.7
Analog inputs
752 to 761
Analog outputs
752 to 755
Digital channels
Inputs
1016
Outputs
1008
Inputs, of which central
1016
Outputs, of which central
1008
Analog channels
Inputs
253
Outputs
250
Inputs, of which central
253
Outputs, of which central
250
Hardware configuration
Racks, max.
4
Modules per rack, max.
8; In rack 3 max. 7
Expansion devices, max.
3
Number of DP masters
integrated
none
via CP
4
Number of operable FMs and CPs (recommended)
FM
8
CP, point-to-point
8
CP, LAN
10
Time of day
Clock
Hardware clock (real-time clock)
Yes
battery-backed and synchronizable
Yes
Deviation per day, max.
10 s
Backup time
6 wk; At 40 °C ambient temperature
Operating hours counter
Number
1
Number/Number range
0
Range of values
0 to 2^31 hours (when using SFC 101)
Granularity
1 hour
retentive
Yes; Must be restarted at each restart
Clock synchronization
supported
Yes
to MPI, master
Yes
to MPI, slave
Yes
in AS, master
Yes
Digital inputs
Number/binary inputs
24
of which, inputs usable for technological functions
16
integrated channels (DI)
24
Input characteristic curve acc. to IEC 61131, Type 1
Yes
Number of simultaneously controllable inputs
horizontal installation
up to 40 °C, max.
24
up to 60 °C, max.
12
vertical installation
up to 40 °C, max.
12
Technological functions
shielded, max.
50 m
Unshielded, max.
not allowed
Standard DI
shielded, max.
1000 m
Unshielded, max.
600 m
Input voltage
Rated value, DC
24 V
for signal "0"
-3 to +5 V
for signal "1"
15 to 30 V
Input current
for signal "1", typ.
9 mA
Input delay (for rated value of input voltage)
for standard inputs
Parameterizable
Yes; 0.1 / 0.3 / 3 / 15 ms
Rated value
3 ms
for counter/technological functions
at "0" to "1", max.
8 µs
Cable length
Cable length, shielded, max.
1000 m; 50 m for technological functions
Cable length unshielded, max.
600 m; For technological functions: No
Digital outputs
Number/binary outputs
16
of which high-speed outputs
4
integrated channels (DO)
16
Functionality/short-circuit strength
Yes; Clocked electronically
Response threshold, typ.
1 A
Limitation of inductive shutdown voltage to
L+ (-48 V)
Lamp load, max.
5 W
Controlling a digital input
Yes
Load resistance range
lower limit
48 Ω
upper limit
4 kΩ
Output voltage
for signal "1", min.
L+ (-0.8 V)
Output current
for signal "1" rated value
500 mA
for signal "1" permissible range, min.
5 mA
for signal "1" permissible range, max.
0.6 A
for signal "1" minimum load current
5 mA
for signal "0" residual current, max.
0.5 mA
Parallel switching of 2 outputs
for increased power
No
for redundant control of a load
Yes
Switching frequency
with resistive load, max.
100 Hz
with inductive load, max.
0.5 Hz
No comment |