6ES7307-1EA01-0AA0 SIEMENS Power Supply Module New

prevnext

6ES7307-1EA01-0AA0 SIEMENS Power Supply Module New
  • Market price: $ 660.0
  • Shop price: $ 200.0
  • Goods click count: 256
  • Total:
  • Quantity:
Add to cart collect
  

Description

6ES7307-1EA01-0AA0 SIEMENS Power Supply Module New

SIEMENS Power Supply Module 6ES7307-1EA01-0AA0

Product Description:

SIMATIC S7-300 STABILIZED POWER SUPPLY PS307 INPUT: 120/230 V AC OUTPUT: DC 24 V DC/5 A.

Features:

Technical specifications

 

Product

PS 307

Power supply, type

24 V/5 A

Input

 

Input

1-phase AC

Supply voltage / 1 / at AC / nominal value

120 V

Supply voltage / 2 / at AC / nominal value

230 V

Voltage range

 

Note

Automatic range selection

Input voltage / 1 / at AC

85…132 V

Input voltage / 2 / at AC

170…264 V

Wide-range input

No

Overvoltage resistance

2.3 × Vin rated, 1.3 ms

Mains buffering at Iout rated, min.

20 ms

Mains buffering

at Vin = 93/187 V

Rated line frequency

50/60 Hz

Rated line range

47...63 Hz

Input current / at nominal level of the input voltage 120 V

2.3 A

Input current / at nominal level of the input voltage 230 V

1.2 A

Switch-on current limiting (+25 °C), max.

20 A

Duration of current limiting / at 25 °C / maximum

3 ms

Inrush current A²s

1.2 A²·s

Built-in incoming fuse

T 3,15 A/250 V (not accessible)

Protection in the mains power input (IEC 898)

Recommended miniature circuit breaker: from 6 A, characteristic C

Output

 

Output

controlled, isolated DC voltage

Rated voltage

24 V

Total tolerance, static ±

3 %

Static mains compensation, approx.

0.1 %

Static load balancing, approx.

0.5 %

Residual ripple peak-peak, max.

50 mV

Residual ripple peak-peak, typ.

10 mV

Spikes peak-peak, max. (bandwidth: 20 MHz)

150 mV

Spikes peak-peak, typ. (bandwidth: 20 MHz)

20 mV

Product feature / output voltage adjustable

No

Output voltage setting

-

Status display

Green LED for 24 V OK

On/off behavior

No overshoot of Vout (soft start)

Startup delay, max.

2 s

Voltage rise, typ.

10 ms

Rated current value Iout rated

5 A

Current range

0…5 A

delivered active power / typ.

120 W

short-term overload current / at short-circuit during run-up / typical

20 A

Duration of overloading ability for excess current / on short-circuiting during the start-up

100 ms

short-term overload current / at short-circuit during operation / typical

20 A

Duration of overloading ability for excess current / on short-circuiting during the operational phase

100 ms

Parallel switching for enhanced performance

Yes

Efficiency

 

Efficiency at Vout rated, Iout rated, approx.

87 %

Power loss at Vout rated, Iout rated, approx.

18 W

Closed-loop control

 

Dynamic mains compensation (Vin rated ±15 %), max.

0.1 %

Dynamic load smoothing (Iout: 50/100/50 %), Uout ± typ.

1 %

Load step setting time 50 to 100%, typ.

0.3 ms

Load step setting time 100 to 50%, typ.

0.3 ms

Protection and monitoring

 

Output overvoltage protection

Additional control loop, shutdown at < 28.8 V, automatic restart

Current limitation

5.5…6.5 A

Characteristic feature of the output / short-circuit protected

Yes

Short-circuit protection

Electronic shutdown, automatic restart

Enduring short circuit current / Effective level / maximum

7 A

Safety

 

Primary/secondary isolation

Yes

Potential separation

Safety extra low output voltage Vout according to EN 60950-1 and EN 50178

Protection class

Class I

stray current / maximum

3.5 mA

stray current / typical

0.5 mA

CE mark

Yes

UL/CSA approval

Yes

UL/cUL (CSA) approval

cULus-Listed (UL 508, CSA C22.2 No. 142), File E143289, UL 1604 Class I Div. 2 Group A, B, C, D, File E330455

Explosion protection

ATEX (EX) II 3G Ex nA II T4; UL 1604 Class I, Div. 2, Group ABCD

FM approval

Class I, Div. 2, Group ABCD, T4

CB approval

No

Marine approval

In S7-300 system

Degree of protection (EN 60529)

IP20

EMC

 

Emitted interference

EN 55022 Class B

Supply harmonics limitation

EN 61000-3-2

Noise immunity

EN 61000-6-2

Operating data

 

Ambient temperature / in operation

0…60 °C

Note

with natural convection

Ambient temparature / on transport

-40…+85 °C

Ambient temparature / in storage

-40…+85 °C

Humidity class according to EN 60721

Climate class 3K3, no condensation

Mechanics

 

Connection technology

screw-type terminals

Connections / Supply input

L, N, PE: 1 screw terminal each for 0.5 ... 2.5 mm² single-core/finely stranded

Connections / Output

L+, M: 3 screw terminals each for 0.5 ... 2.5 mm²

Connections / Auxiliary

-

Width / of the housing

60 mm

Height / of the housing

125 mm

Depth / of the housing

120 mm

Installation width

60 mm

Mounting height

205 mm

Weight, approx.

0.6 kg

Product feature / of the housing / housing for side-by-side mounting

Yes

Type of mounting / wall mounting

No

Type of fixing / cap rail mounting

No

Type of mounting / S7-300 rail mounting

Yes

Installation

Can be mounted onto S7 rail

Mechanical accessories

Mounting adapter for standard mounting rail (6EP1971-1BA00)

Other information

Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)

 



  