Your Position: Home > Low Voltage > Others Electrical > DTC1000V Delta Temperature Controller Input DC24Voutput relay &12V with RS485 New

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

DTC1000V Delta Temperature Controller Input DC24Voutput relay &12V with RS485 New

prevnext

DTC1000V Delta Temperature Controller Input DC24Voutput relay &12V with RS485 New
  • Market price: $ 214.5
  • Shop price: $ 65.0
  • Goods click count: 406
  • Total:
  • Quantity:
Add to cart collect
  

Description

DTC1000V Delta Temperature Controller Input DC24Voutput relay &12V with RS485 New

Delta Temperature Controller (TC) DTC Series:

Features

The modulized DTC series saves wiring and the parallel modules are able to monitor many temperature points. The flexible output methods enable the user to plan the output modes according to the actual needs. The built-in password protection prevents improper operation or damages caused by the operation staff.

Specifications

PID / On-Off / manual input / programmable control models

2 groups of outputs for auto-tuning 2 groups of PID parameters

Able to connect to various thermocouples (B, E, J, K, L, N, R, S, T, U, TXK), platinum RTD (PT100, JPT100), analog current (0 ~ ?20mA, 4 ~ 20mA) and linear voltage (0 ~ 5V, 0 ~ 10V) .

Maximum 2 groups of alarm switches are available, with 12 alarm modes each.

LED status display

Celsius or Fahrenheit temperature display.

Built-in RS-485 communication interface (Modbus ASCII, RTU, baud rate: 2,400 ~ 38,400)

Sampling time of thermocouple/platinum RTD: 0.4 second/time; sampling time of analog input: 0.15 second/time.

Programmable logic controller is able to set up 64 sets of temperature and control time.

3 levels of password protection; wire saving; synchronous communication protocol setting; ID auto setting

Function & Specification

Power supply

DC24V. Isolated switching power

Power consumption

Rated 24 VDC, Max. 24 W combined, 3W + 3W x number of DTC2000/2001

controllers (Max. 7)

Input sensors

Platinum RTD: Pt100, JPt100 

Linear DC input: 0 ~ 5V, 0 ~ 10V, 0 ~ 20mA, 4 ~ 20mA, 0 ~ 50mV

Sampling rate

Analog input: 0.15 sec. Thermocouple or platinum RTD: 0.4 sec.

Control method

PID , programmable PID, Manual, ON/OFF

Output types

Relay: SPST, Max. load 250VAC, 3A resistive load

Voltage pulse: 12VDC, Max. output current: 40mA

Current: DC 4 ~ 20mA (Load resistance: < 500?)

Analog voltage: 0 ~ 10V (Load resistance: > 1,000?)

Ambient temperature

0 ~ 50 ° C

Ambient humidity 

35% ~ 85% RH (non-condensing)

Pollution degree

2

 

  