Your Position: Home > Low Voltage > Breaker > DPNA VIGI 20A Schneider Breaker NEW

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

DPNA VIGI 20A Schneider Breaker NEW

prevnext

DPNA VIGI 20A Schneider Breaker NEW
  • NO.: DPNA
  • Weight: 200gram
  • Market price: $ 92.4
  • Shop price: $ 28.0
  • Goods click count: 299
  • Total:
  • Quantity:
Add to cart collect
  

Description

DPNA VIGI 20A Schneider Breaker NEW

 Schneider Breaker DPNA VIGI 20A

Product Description:

DPNa vigi Residual current operated circuit breaker

Type C tripping curve

IEC 61009 / GB 16917: 4500A

30 mA, instantaneous action-type AC type

DPNa vigi residual current operated protective attachment circuit breakers can achieve the comprehensive protection of the terminal distribution lines. It

At the same time cut off the phase line and neutral line, neutral line does not provide protection. It can be realized:

- Overload Protection

- Short-circuit protection

- Isolation

- Control functions

- To provide personal protection for indirect contact

- Direct contact to provide additional personal protection

- Provide protection for the insulation of electrical equipment failure

Technical parameters

? Rated current: 10 ~ 20 A (30 ° C)

? Rated voltage: 230 V

? Breaking capacity: 4.5 kA (IEC 61009 / GB 16917)

? residual operating current: 30 mA, AC class

? Electronic residual current operated protective filtering device, to prevent transient over-voltage equipment (lighting, line dry

Interference) and instantaneous overcurrent (such as a capacitive load line) caused by the malfunction trip

? Tripping characteristics: C-type instantaneous trip range (5 to 10) In

? release instructions

? Vigi Annex operating handle on red Residual current operated trip indication

? Manual control: handle allows two kinds of reset mode, easy to distinguish the type of fault

? circuit breakers and residual current operated attachments at the same time to reset (overload / short circuit fault trip)

? circuit breakers and residual current operated attachments reset, residual current operated attachment to reset, reset circuit breaker after (left

I current action fault trip)

? Mechanical life: 20,000 times

? Environmental

For ambient temperature: -25 ° C to +55 ° C

? Kangshire: Class 2 (temperature 55 ° C, relative humidity 95%)

? Wiring: 16 mm2

And below the wire

? width: 36 mm (four times the modulus)

? Standard and Certification

Compliance with IEC 61009-1 / GB 16917 standards and CCC safety certification

Attachment

? can be equipped with DPN comb busbar

? with the C65 electrical accessories

? OF: Status indication contacts

? SD: alarm contacts

? the MX or MX + OF: shunt trip unit

? MN MNs: undervoltage release unit

? MV: over-voltage trip unit




  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: